AUTOOL LM100 Smart Digital Vaccum Gauge

(1 customer review)

US$120.00

Secure checkoutFast supportBulk ready
AUTOOL LM100

Product Overview

AUTOOL LM100 Intelligent Digital Vacuum Gauge is a powerful digital vacuum gauge for refrigeration, HVAC, and automotive A/C service. Built with high-strength engineering plastics, soft non-slip silicone, a brass valve body, and a foldable hook, it combines rugged durability with comfortable handheld operation. Equipped with a high-precision sensor, it delivers measurement accuracy up to ±0.2% and resolution as fine as 0.1 mbar. The 2.8-inch backlit display, evacuation mode, pressure retention test mode, one-button 7-unit switching, automatic sleep function, and LM130 data transmission support make it a compact and practical tool for vacuum monitoring and refrigeration system sealing checks.

±0.2% Accuracy 0.1 mbar Resolution Evacuation Mode LM130 Data Transfer
2.8-inchBacklit Display
7 UnitsOne-Button Switch
20 minAuto Sleep
3 YearsWarranty
AUTOOL LM100 smart digital vacuum gauge main product image Click to enlarge
AUTOOL LM100 three year warranty image Click to enlarge
Key Features

Key Features

LM100 focuses on accurate vacuum measurement, refrigeration system sealing checks, LM130 synchronized data transfer, and portable field operation.

Accurate Data Measurement

Equipped with a high-precision sensor, LM100 offers measurement accuracy up to ±0.2% and vacuum resolution up to 0.1 mbar.

Data Transmission With LM130

The integrated microprocessor and communication interface enable synchronized data transfer when connected with the AUTOOL LM130.

Pressure Retention Test

Pressure retention test mode helps detect the sealing condition of refrigeration systems and supports small-leak inspection.

Portable Durable Build

High-strength engineering plastics, soft anti-slip silicone, brass valve body, and foldable hook support rugged daily service use.

Key Features

Key Features

LM100 combines high-precision measurement, evacuation monitoring, leak testing, backlit display, unit switching, and practical structure design for refrigeration and A/C service work.

High-Precision Sensor

Measurement accuracy up to ±0.2%, vacuum resolution up to 0.1 hPa / 0.1 mbar / 0.1 Torr / 0.01 inHg, and temperature accuracy up to ±0.5°C / ±0.9°F / ±0.5K.

Evacuation Mode

Quickly monitors air and moisture removal during refrigeration system evacuation and displays vacuum level changes in real time.

Pressure Leak Test Mode

Pressure retention test mode helps accurately inspect refrigeration system sealing condition and identify small pressure changes.

LM130 Data Transmission

Connects with LM130 through the integrated communication interface for high-precision synchronized data transmission.

2.8-Inch Backlit Display

The high-definition backlit display is suitable for dim and bright environments, with 0.5-second response time for quick reading.

User-Friendly Structure

Foldable hook, multi-button layout, silicone side grip, brass connector, and automatic power-off after 20 minutes of inactivity improve field usability.

Specifications

Specifications And Pressure Safety Limits

Confirm vacuum range, unit support, temperature range, pressure limits, hose pressure rating, display, and operating environment before testing.

Measurement
Vacuum UnitshPa, mbar, Torr, inHg
Temperature Units°C, °F, K
Vacuum Range0-2000 mbar / 0-1500 Torr
Absolute Pressure Display0-2000 mbar
Vacuum Resolution0.1 hPa / 0.1 mbar / 0.1 Torr / 0.01 inHg
Vacuum AccuracyWithin ±0.2% of full range
Temperature Range-55-125°C / -67-257°F / 218-398K
Temperature Resolution0.1°C / 0.1°F / 1K
Temperature Accuracy±0.5°C / ±0.9°F / ±0.5K
Device
Display2.8-inch backlit display
Response Time0.5 seconds
Operating Temperature-10-60°C
Operating Voltage6V, 4 × 1.5V batteries
Auto SleepAutomatically powers off after 20 minutes of inactivity
BodyHigh-strength engineering plastics and soft anti-slip silicone
ConnectorBrass valve body / refilling tube brass connector
HookFoldable hook design
Pressure Safety
Gauge Pressure Range-101 kPa to 6 MPa / -0.1 bar to 60 bar
Absolute Limit10 MPa / 100 bar
Standard Hose Max Working Pressure600 PSI / about 4.13 MPa / 41.3 bar
Standard Hose Limit3000 PSI / about 20.68 MPa / 206.8 bar
Measurement
Vacuum UnitshPa, mbar, Torr, inHg
Temperature Units°C, °F, K
Vacuum Range0-2000 mbar / 0-1500 Torr
Vacuum Resolution0.1 hPa / 0.1 mbar / 0.1 Torr / 0.01 inHg
Vacuum AccuracyWithin ±0.2% of full range
Temperature Range-55-125°C / -67-257°F / 218-398K
Temperature Accuracy±0.5°C / ±0.9°F / ±0.5K
Device
Display2.8-inch backlit display
Response Time0.5 seconds
Operating Temperature-10-60°C
Operating Voltage6V, 4 × 1.5V batteries
Auto SleepAutomatically powers off after 20 minutes of inactivity
BodyHigh-strength engineering plastics and soft anti-slip silicone
HookFoldable hook design
Pressure Safety
Gauge Pressure Range-101 kPa to 6 MPa / -0.1 bar to 60 bar
Absolute Limit10 MPa / 100 bar
Standard Hose Max Working Pressure600 PSI / about 4.13 MPa / 41.3 bar
Standard Hose Limit3000 PSI / about 20.68 MPa / 206.8 bar
Product Comparison

Product Comparison

LM100 is positioned as a smart digital vacuum gauge for vacuum monitoring and pressure leak testing. Compare it with AUTOOL LM120, LM120+, LM130, LM150, and LM160 before choosing a complete A/C gauge or refrigerant tool.

LM100 FocusVacuuming mode, pressure leak test, foldable hook, vacuum units, temperature units, and LM130 data transmission support
Compared With LM120 / LM150 / LM160LM120, LM150, and LM160 focus more on refrigerant mode, high / low pressure valve use, refrigerant database, and manifold testing
Compared With LM130LM100 can connect with LM130 for synchronized data transmission, while LM130 itself is a separate digital manifold gauge tool
Decision CheckChoose LM100 for vacuum monitoring and pressure retention leak tests; compare LM120 / LM150 / LM160 if refrigerant filling, manifold functions, or refrigerant database support is required
AUTOOL air conditioning system tester comparison chart Click to enlarge
Manual And Downloads

Manual And Downloads

Download the AUTOOL LM100 user manual for setup, unit switching, evacuation mode, pressure leak test mode, safety limits, and maintenance guidance.

AUTOOL LM100 user manual preview Click to enlarge

AUTOOL LM100 User Manual

Open the PDF manual for LM100 operation, safety limits, pressure leak test mode, evacuation mode, and unit settings.

Download Manual
Related Products

Related Products

Compare related AUTOOL digital manifold gauges and refrigerant tools before choosing the right gauge type, refrigerant function, and testing workflow.

Related Guides

Related Guides

Use these related articles to understand refrigerant service context, manifold-gauge decisions, and A/C workflow before using LM100.

AUTOOL LM100 packing list and package contents Click to enlarge
What Is In The Box

What Is In The Box

Review the package image to confirm the LM100 main unit, product box, user manual, and included accessories before ordering. Packing List uses the most relevant single package image only.

Main UnitAUTOOL LM100 Smart Digital Vacuum Gauge
ManualUser manual shown in the package image
Connection CableData / connection cable shown in the package image
ConnectorBrass valve connector shown in the package image
Short HoseYellow short hose shown in the package image
PackagingProduct box shown in the package image
Before You Order And Use

Before You Order And Use

LM100 has defined pressure limits, hose pressure limits, environmental restrictions, and safety requirements. Confirm the rated pressure of the system before testing.

Safety And Use Notes

  • LM100 measures gauge pressure with a range of -101 kPa to 6 MPa / -0.1 bar to 60 bar.
  • The absolute pressure limit is 10 MPa / 100 bar.
  • The standard hose maximum working pressure is 600 PSI / about 4.13 MPa / 41.3 bar.
  • The standard hose limit is 3000 PSI / about 20.68 MPa / 206.8 bar.
  • Before testing, confirm the rated pressure of the equipment being tested.
  • Do not use the LM100 if the test pressure exceeds its rated range.
  • For DY517A, if the charging hose does not meet pressure requirements, use a suitable replacement hose for testing.
  • Do not use or store this refrigerant leak detector in high temperature, high humidity, flammable, explosive, or strong electromagnetic environments.
  • Do not modify the internal circuitry of the LM100 to avoid damage or potential hazards.
  • Wear proper protective equipment during testing.
  • Use the instrument in a well-ventilated environment to avoid inhaling toxic gases.

Questions And Answers

These answers cover LM100 use, refrigerant mode limitations, LM130 connection, unit switching, vacuum range, pressure limits, auto sleep, and package contents.

Warranty And Contact

Warranty And Contact

For LM100 support, manual requests, pressure range confirmation, LM130 data transmission setup, hose / connector pressure compatibility, refrigeration system leak test guidance, or warranty questions, contact AUTOOL Store directly.

Pre-Sales And Product Support

Use support if you need help confirming whether LM100 is suitable for your refrigeration, HVAC, or automotive A/C vacuum test task; checking rated pressure; selecting a suitable hose; or understanding the difference between LM100 and AUTOOL digital manifold gauges.

  • 3-year warranty for eligible non-human damage cases
  • Lifetime maintenance support
  • Manual and setup support
  • Pressure range and hose compatibility confirmation
  • LM130 data transmission support
  • Refrigeration system leak test guidance

Customer Reviews

There are no reviews yet.

Leave A Review

Your email address will not be published. Required fields are marked *

AUTOOL LM130 Refrigeration Digital Gauges
AUTOOL LM100 Smart Digital Vaccum Gauge

US$120.00

Add to cart This product has multiple variants. The options may be chosen on the product page