AUTOOL SDT50 · Compact Smoke Leak Detector with Built-In Pump

Carry Self-Contained Smoke Testing Between Bays

Use this automotive smoke leak detector for permitted low-pressure checks in different locations without an external air supply. The built-in pump starts producing smoke in about five seconds, while the compact 1.5 kg body supports visual tracing across approved intake, exhaust, fuel-tank, crankcase, sealing, line-fitting, and coolant-tank paths.

  • Built-In Pump, No Shop Air
  • About 5-Second Smoke Start
  • 1.5 kg Main Unit
  • Permitted Low-Pressure Systems
  • Cold And Overheat Protection
AUTOOL SDT50 smoke leak detector

Key Features

Portable Built-In Air and Smoke Generation

Smoke Starts in About 5 Seconds

Smoke generation starts in about 5 seconds, helping users locate leaks sooner.

Built-In Air Pump

No external air supply is required. The built-in pump keeps setup simple for testing in different locations.

Intake / Exhaust / Fuel Tank / Crankcase Leak Checks

Supports checks for crankcase, oil seal, intercooler air, throttle valve, intake manifold, exhaust, fuel tank, line fittings, and coolant tank.

Lightweight and Portable

The SDT50 smoke leak detector weighs only 1.5 kg, takes up little storage space, and is easy to carry for mobile diagnostics.

High / Low Temperature Protection

The unit automatically powers off at 75°C and supports operation down to -20°C.

Controls & Connections

The filling port, smoke indicator switch, hook port, power socket, and smoke outlet are grouped on the unit for quick identification during setup and leak testing.

3 Years Warranty Support

Main unit: 3-year warranty. Standard accessories: 1-year warranty. Warranty Policy.

How to Use

Add Oil, Connect, Power, Inspect, and Retest

Step progress1 / 5
01

Add Testing Oil

Fill 10–15 mL baby oil or liquid paraffin into the detector before first use. Do not exceed this range.

Safety & Compatibility

Confirm System Pressure, Ventilation, and Connections

12V Power and Built-In Air Pump

The built-in pump supplies test airflow after SDT50 is connected to a 12V DC battery.

Add 10–15 mL of Testing Oil

Use liquid paraffin or baby oil as testing oil. Add 10–15 mL before first use and do not exceed 15 mL at one time.

Limit Continuous Use to 8 Minutes

Do not run SDT50 continuously for more than 8 minutes. If the internal temperature exceeds 75°C, the unit shuts off automatically. Let it cool before restarting.

Operating Temperature and Hot Surfaces

SDT50 supports operation down to -20°C. The round metal housing can become hot during use, so avoid touching hot surfaces directly.

Check Connections Before Starting Smoke

Before starting smoke, make sure the smoke hose and test line are connected securely. Follow the vehicle or component service procedure, and do not introduce smoke into any system where smoke testing is not permitted.

Use Smoke to Locate the Leak

Use visible smoke to locate the leak area, then repair and retest. If no smoke appears, recheck isolation, flow, and the test setup before continuing.

Never Refill While Running

Do not refill testing oil while SDT50 is running.

No Pressure or Airflow Measurement

Do not use SDT50 to measure pressure or airflow.

Cool Before Restarting

Let the unit cool before restarting after overheat protection is triggered.

Avoid Hot Metal Housing

Avoid touching the metal housing when it is hot.

Compare Models

Compare Compact Smoke Leak Detectors

Model Guide

Choose one or more models. SDT50 is selected by default.

1 model selected

AUTOOL SDT50 is selected. Choose another model for a side-by-side comparison.

SDT50 comparison

Comparison of AUTOOL Smoke Leak Detectors
Product NameSDT50
Smoke Output & Protection
Working Principle
Low Oxygen Combustion
Test Oil Filling Volume
10-15ml
Rated Output Pressure
<10 psi machine-rated output; use the target-system procedure.
Rated Output Flow
<5L/min
High-Temperature Protection
Stops working above 75°C
Response Time
Produces smoke in 5 seconds
Power & Physical Size
Input Power
DC12V
Rated Power
50W
Net Weight (Main Unit)
1.5kg
Main Unit Dimensions
145mm*80mm*200mm
Monitoring & Controls
Flow Meter Window
×
Pressure Gauge
×
Air Source Type
Built-in Air Pump
Mode Output
Smoke Mode
Dual Pressure Mode
×
Flow Adjustment Knob
×
Oil Drain Valve
×
Fault Indicator Light
×
Oil Level Gauge
×

Manual & Downloads

Use the Manual for Setup and Test Pressure

AUTOOL SDT50 user manual cover
Manual / PDF

AUTOOL SDT50 User Manual

Open the PDF manual for SDT50 built-in pump operation, permitted low-pressure smoke tests, system connections, test-oil handling, safety, maintenance, and troubleshooting.

AUTOOL SDT50 package contents

Package

What’s Included

  • Main UnitAUTOOL SDT50 Smoke Leak Detector
  • Power Cable12V battery clamp cable
  • Smoke HoseSmoke output hose
  • Filling AccessoriesFunnel and filling bottle
  • HookHanging hook
  • DocumentationUser manual
  • Testing OilNot included; use liquid paraffin or baby oil

FAQs

Power, Pump, and Smoke Questions

Does SDT50 Need an External Air Pump?

No. AUTOOL SDT50 has a built-in air pump, so it does not require a separate air supply or extra air pump for normal smoke leak detection.

What Testing Oil Should I Use?

Liquid paraffin and baby oil are both acceptable testing oils for SDT50. Replace the testing oil regularly, and drain remaining old oil before adding fresh oil.

How Much Oil Should I Add?

Fill 10–15 mL oil before first use. Do not exceed this range. Fresh oil can be added only when smoke becomes thin, and do not add more than 15 mL each time.

What Power Supply Does SDT50 Need?

SDT50 must be connected to a 12V DC battery and is designed for 12V DC vehicle leak checks.

How Long Can SDT50 Run Continuously?

Do not run the detector continuously for more than 8 minutes. Allow the unit to rest between operating cycles.

Why Did the Unit Shut Off Automatically?

If the temperature exceeds 75°C, automatic overheat protection turns off the power. Let the unit cool before restarting.

Is Any Part of the Detector Hot During Operation?

Yes. The round metal housing can become hot during operation. Avoid direct contact to prevent burns.

Should I Avoid Any Parts During Leak Detection?

Yes. Do not introduce smoke into any component or system that the vehicle or component service procedure excludes from smoke testing.

How Does SDT50 Differ from Other AUTOOL Smoke Leak Detectors?
  • SDT50: Built-in pump, Smoke Mode, <10 psi, <5 L/min, 50 W, 1.5 kg.
  • Add pressure monitoring: SDT60.
  • External-air EVAP: SDT101/103.
  • Separate Air + Smoke modes: SDT205/205S/206/208; SDT208 also provides 35 psi Standard and 10 psi EVAP.

Customer Reviews

  1. TH

    Tim Hendry ✓ Verified Purchase –

    Good smoke effect

    Very good quality, better than other brands I have used before. This smoke leak detector has a built-in air pump. It is small and easy to carry. I can use it easily. The smoke effect is good. A lot of smoke is produced in 20 seconds. I use baby oil.

    0 of 0 found this review helpful
  2. OS

    Otto Sam ✓ Verified Purchase –

    Pipe inspection is very useful.

    Pipe inspection is very useful. Although it is very small, it has a built-in air pump, so it can be used for inspection at any time without the need for an additional air source, providing greater convenience. I am very satisfied with it.

    0 of 0 found this review helpful
  3. D

    David ✓ Verified Purchase –

    The smoker is a great product, portable and lightweight, I used the Johnson's…

    The smoker is a great product, portable and lightweight, I used the Johnson’s baby oil they recommended to go with it, it’s an amazing combo, but the smoke comes out very well, I have a repair tool sales store, can I resell it please? Please contact me, thanks!

    0 of 0 found this review helpful
Leave A Review

Your email address will not be published. Required fields are marked *

Choose your language

Choose your language

Prefer another language?

Continue
Language
AUTOOL SDT50 Automotive Smoke Leak Detector with Built-In Air Pump
AUTOOL SDT50 Automotive Smoke Leak Detector with Built-In Air Pump

US$85.00

Select options This product has multiple variants. The options may be chosen on the product page
Get Extra Discount