AUTOOLautoolstore.com
Source: https://autoolstore.com/product/autool-lm150-digital-manifold-gauges-digital-ac-gauges/

AUTOOL LM150 Digital Manifold Gauge with 93-Refrigerant Database

(5 customer reviews)

US$159.00

  • 3-Year Warranty Main unit 3 years · Accessories 1 year
  • 90-Day Returns Eligible returns within 90 days
  • Official Store Genuine products · Direct support

AUTOOL LM150 · 93-Refrigerant AC Manifold Gauge with Dual Temperature

Read Pressure and Dual Temperatures Together

Measure 0–6 MPa high- and low-side pressure alongside two pipe temperatures using the included wired clamps. Select from 93 refrigerant profiles to calculate superheat/subcooling, then monitor relative vacuum or timed pressure retention. V-shaped ball valves, a sight window and 1/4-inch connections support charging, while the 3.5-inch backlit display and IP54 shell suit workshop handling.

  • 0–6 MPa Gauge Pressure
  • 93 Refrigerant Profiles
  • 2 Included Temperature Clamps
  • Superheat / Subcooling
  • 3.5-Inch Backlit Display
AUTOOL LM150 digital manifold pressure tester for automotive AC and HVAC service

Key Features

A 93-Refrigerant Library with Two Clamp Channels

Dual-Channel Gauge Pressure

Read high- and low-side pressure together within the stated range.

Two Wired Temperature Clamps

Use the two included wired T1/T2 clamp probes for live pipe-temperature readings during evaporation and condensation checks. Maintain full contact with the refrigeration pipes for stable measurements.

93-Refrigerant Database

Select the known refrigerant from the 93-profile NIST-standard database to view its operating data during service.

Superheat And Subcooling

Calculate SH/SC from the selected refrigerant, pressure readings and stable T1/T2 measurements.

Vacuum Monitoring

Follow relative vacuum during system evacuation.

Pressure-Retention Testing

Record initial pressure, current pressure, pressure difference and elapsed time during a retention check to assess system tightness. Vacuum-pressure and vacuum-percentage readings support evacuation monitoring, while refrigerant filling assistance supports the system-specific charging procedure.

Charging Assistance

Use valves, the refrigerant sight window and rated hoses during the approved system-specific charging sequence.

3.5-Inch Backlit Display

Measures high-pressure and low-pressure line pressure, high-pressure and low-pressure line temperature, evaporation temperature, and condensation temperature for clearer service decisions. View pressure, temperature, selected refrigerant and test status together.

V-Shaped Ball Valves

Control the high- and low-side flow paths directly with the V-shaped ball-valve design during compatible service steps.

Portable Kit Hardware

Non-slip housing, foldable hook, standard connections, three-color hoses and hard case support transport and use.

IP54 Anti-Slip Housing

The body uses high-strength engineering plastics and flexible anti-slip silicone. The shell is IP54-rated and designed for stable handling in workshop use.

Durable Interface Design

Long-life valve switches, refrigerant observation window, pressure release valve, and 1/4-inch standard interfaces improve daily service usability.

3 Years Warranty Support

Main unit: 3-year warranty. Standard accessories: 1-year warranty. Warranty Policy.

How to Use

Connect, Select, Stabilize, and Compare Both Lines

Step progress1 / 5
01

Identify The Refrigerant

Confirm the exact refrigerant and service information before selecting one of the 93 profiles.

Safety & Compatibility

Verify Refrigerant, Couplers, Hoses, and Pressure

Gauge Pressure Only

Interpret LM150 readings as gauge pressure and stay within -101 kPa to 6 MPa measurement coverage.

Hose Rating Can Govern

Standard hoses are listed for 600 PSI working pressure; 3000 PSI is a burst value, not a service target.

Check Hose Ends And Seals

Incorrect core orientation or worn nylon pads can prevent filling or cause leakage.

Use PPE And Ventilation

Wear appropriate protection, ventilate the area and avoid hazardous heat, humidity, ignition and electromagnetic conditions.

Use Known Refrigerant Data

Select the known refrigerant before interpreting readings or charging.

Restricted Operating Environments

Do not use or store the device in high temperature, high humidity, flammable, explosive, or strong electromagnetic field environments.

No Circuit Modifications

Do not modify the internal circuit. Unauthorized modification may damage the instrument or create hazards.

Inspect Service Connections

Inspect pipe fittings, hoses, hose terminals, and valve stems before testing. Replace damaged parts before use.

Release Pressure Before Disconnecting

Do not remove the high-pressure valve connection until the pressure drops to a safe point.

Follow System Charging Procedures

Different equipment and refrigerants may require different filling procedures. Follow the refrigeration system service requirements before charging.

Maximum Device Pressure

The maximum device pressure / overload limit is 10 MPa / 100 bar. This is not the normal measuring range and does not permit exceeding the rated pressure of the tested system.

Test Results

Interpret Pressure, Temperature, SH, and SC

Read Pressure and Temperature Together

Interpret high- and low-side pressure together with T1/T2 temperature values, the known refrigerant, and operating condition.

SH/SC Validity

Requires correct refrigerant selection and stable full clamp contact.

Retention Change

Recheck hoses, pads, fittings and valve stems before moving to a separate leak-location procedure.

Post-Service Readings

Abnormal pressure or cooling can require additional electrical, mechanical, airflow or leak diagnosis.

Compare Models

Compare Refrigerant Libraries and Inputs

Model Guide

Choose one or more models. LM150 is selected by default.

1 model selected

LM150 is selected. Choose another model for a side-by-side comparison.

LM150 comparison

Compare Your Options
Choose For Your TaskLM150
Selection Criteria
Refrigerant profiles
93
Program-controlled menu
No verified support
Wired clamps in package
Two shown

Manual & Downloads

Use the Manual for Setup and Service

AUTOOL LM150 user manual cover
Manual / PDF

AUTOOL LM150 User Manual

Open the PDF manual for LM150 pressure and temperature measurement, refrigerant selection, superheat and subcooling, vacuum and charging procedures, safety, and troubleshooting.

AUTOOL LM150 packing list with main unit storage case hoses adapters manual retail box and two temperature clamp probes

Package

What’s Included

  • LM150 Main UnitDigital manifold pressure tester.
  • Hard Storage CaseProtective carrying case.
  • Three-Color Hose SetRed, blue and yellow service hoses; confirm rating for the application.
  • Two Wired Temperature ClampsT1/T2 clip-on pipe probes.
  • Adapters And Brass ConnectorSmall adapters/connector; confirm the exact selected-kit pieces.
  • Manual And Retail BoxDocumentation and packaging.

FAQs

Refrigerant Library and Clamp Questions

What Is AUTOOL LM150 Used For?

LM150 is a digital manifold pressure tester for HVAC installation, refrigeration equipment testing and maintenance, automotive A/C service, air conditioners, and cold storage systems. It supports dual pressure testing, dual temperature testing, refrigerant service, vacuum measurement, and pressure leak testing.

  • High/low gauge pressure, relative vacuum and two pipe temperatures; it also supports timed retention and selected-refrigerant calculations.
How many refrigerants are stored?

LM150 lists 93 refrigerants in its NIST-standard reference database.

Are Temperature Clamps Included?

Yes. LM150 includes two wired clip-on temperature probes. Connect them to the T1 and T2 sockets with full pipe contact for real-time temperature readings.

Does LM150 identify refrigerant?

No. Select only refrigerant already confirmed from vehicle/equipment information.

Can it locate a leak?

No. Pressure change can flag a problem; use an approved separate method to locate it.

Why Might Refrigerant Filling Fail?

The refrigeration system inlet has a valve core. When connecting hoses, pay attention to both hose terminals: connect the terminal with a core to the refrigeration system and the terminal without a core to the instrument.

  • Check hose-end valve-core orientation, then inspect seals, fittings and valves and follow the connection procedure.
What Is The Standard Hose Pressure Limit?

The maximum working pressure of the standard hose is 600PSI, approximately 4.13MPa / 41.3bar. The hose burst pressure is 3000PSI, approximately 20.68MPa / 206.8bar. If the included hose does not meet your pressure requirement, use a suitable replacement hose.

  • Use the lowest system, gauge and hose working rating. Do not treat the 100 bar instrument limit or 3000 PSI hose burst value as normal operation.
What powers it?

Four 1.5 V AA/LR6 batteries.

How does it differ from LM160?

LM150 provides the core 93-refrigerant dual-clamp manifold workflow; LM160 adds program control, eight languages and a 95-refrigerant database.

Is The Pressure Reading Gauge Pressure Or Absolute Pressure?

The LM150 pressure reading is gauge pressure. Confirm whether the system procedure requires gauge pressure or another pressure reference before interpreting test data.

What Is The LM150 Pressure Test Range?

The overall pressure and vacuum coverage is -101 kPa to 6 MPa, approximately -1.01 bar to 60 bar. The pressure test range is 0 kPa to 6000 kPa, and the vacuum test range is -101 kPa to 0 kPa. Do not use it beyond the measuring range of the instrument.

How Many Refrigerants Does LM150 Support?

LM150 includes a built-in 93-refrigerant NIST-standard database. Confirm that your required refrigerant is included before ordering.

What Power Supply Does LM150 Need?

LM150 uses 4 × 1.5V AA / LR6 batteries. If the low-power sign appears, replace the batteries as required to avoid affecting normal use.

What Should I Check Before Testing?

Check the rated pressure of the tested equipment, confirm that the system does not exceed the instrument range, inspect pipe fittings and hoses, replace damaged parts immediately, wear approved protective equipment, and work in a well-ventilated area.

What Are Common Leak Points To Check?

Check hose terminals, nylon pads, pipe fittings, hoses, valve stems, and refrigeration system pipes and connectors. Hose terminal nylon pads have a limited service life, and overuse or damage may cause leakage. Tighten the copper plug screw on the middle refrigerant inlet before or after operation as required.

What Is The Difference Between LM150 And LM160?

LM150 supports vacuuming mode, refrigerant mode, pressure leak testing, 93 refrigerants, high/low pressure valves, two wired temperature clamps, a foldable hook, and a refrigerant sight window. LM160 adds program control, 8 interface languages, a 95-refrigerant database, and two-side handrails; choose it when those functions are required.

How Long Is The Warranty?

Main unit: 3-year warranty. Standard accessories: 1-year warranty. Warranty Policy.

Customer Reviews

  1. FG

    Ford Gladstone ✓ Verified Purchase –

    Looks awesome it's going to be a while before I get around to using it

    Looks awesome it’s going to be a while before I get around to using it

    0 of 0 found this review helpful
  2. VL

    Victoria Leigh ✓ Verified Purchase –

    good

    Diese Monteurshilfe ist top. Sehr robust und nach neuestem Standart. Für mich die richtige Entscheidung.

    0 of 0 found this review helpful
  3. AD

    Amy Dru ✓ Verified Purchase –

    Very nice manifold set.

    Pros:
    1. LCD read out means no more bouncy gauges and guess work.
    2. Takes 2 batteries – easy enough.
    3. Materials are heavy duty and the unit appears very well made.
    4. Reads low and high pressure side.
    5. Worked with my vacuum pump and filling setup – required same adapters most require.

    Cons:
    1. Something this nice deserves a nice storage case to protect it – most people will just leave it hanging up though.

    0 of 0 found this review helpful
Leave A Review

Your email address will not be published. Required fields are marked *

Choose your language

Choose your language

Prefer another language?

Continue
Language
LM150 Digital Manifold Gauges Digital AC Gauges
AUTOOL LM150 Digital Manifold Gauge with 93-Refrigerant Database

US$159.00

Select options This product has multiple variants. The options may be chosen on the product page
Get Extra Discount