AUTOOL SML310 Automotive Smoke Leak Detector
US$499.00
- Air + Smoke Modes
- Built-In Air Pump
- Visual Pressure Gauge
- Oil Drain Valve
- Air + Smoke Modes: Use an air-only pressure stage before switching to smoke for visual leak localization.
- Built-In Air Pump: Run routine tests without a separate shop-air compressor.
- Visual Pressure Gauge: Watch pressure behavior while the connected test volume fills, then inspect unstable or falling readings with smoke.
- Oil Drain Valve: Drain aged or excess smoke oil before refilling or storing the machine.
- Smoke in About 5 Seconds: Begin smoke output in about five seconds after the prepared system is activated.
- 3-Year Warranty Main unit 3 years · Accessories 1 year
- 90-Day Returns Eligible returns within 90 days
- Official Store Genuine products · Direct support
AUTOOL SML310 · Smoke Tester with Air Mode and Oil Drain
Check with Air Before Tracing with Smoke
Use this automotive smoke leak detector in an air-only stage to watch pressure behavior in the connected test volume, then switch to smoke to inspect the visible leak path. SML310 combines a built-in pump, pressure gauge, fast smoke output, and an oil drain valve for routine permitted low-pressure testing without a separate shop-air compressor.
- Separate Air And Smoke Modes
- Built-In Pump, No Shop Air
- Pressure-Gauge Feedback
- Oil Drain Valve
- About 5-Second Smoke Start

Key Features
Air and Smoke Modes with Pressure Monitoring
Air and Smoke Modes
Use an air-only or pressure stage before switching to smoke for visual localization, following the model controls and system procedure.
Built-In Air Pump
The internal pump supplies test airflow, so routine setup does not require a separate shop-air compressor.
Visual Pressure Gauge
Watch pressure behavior while the connected test volume fills, then use Smoke mode to inspect any unstable or falling reading.
Oil Drain Valve
Empty aged or excess smoke oil through the drain valve before refilling or storing the machine.
Smoke in About 5 Seconds
Smoke starts in about five seconds after the prepared system is connected and the mode is activated.
Overheat Shutdown Above 75°C
Temperature protection stops operation when the model reaches its protection condition; allow the unit to cool before further use.
65W Rated Power
The 65 W rating works with the specified 12 V / 5 A supply; use a stable vehicle-battery connection.
3 Years Warranty Support
Main unit: 3-year warranty. Standard accessories: 1-year warranty. Warranty Policy.
How to Use
Prepare, Check with Air, Add Smoke, Inspect, and Retest
Confirm the Procedure
Identify the target system, permitted pressure or threshold, access point, valve state and openings that must be sealed.
Prepare the Machine
Inspect the power lead, air connection where required, hose and adapters. Add or confirm only the smoke oil specified by the manual.
Connect and Isolate
Use the correct adapter, make a leak-free connection to the selected test point, and isolate normal escape paths according to the vehicle procedure.
Run Air Mode and Watch the Gauge
Use Air Mode first and observe the pressure gauge under the selected test conditions.
Use Smoke to Inspect
Switch to Smoke mode when visual tracing is needed, allow the connected volume to fill, and inspect accessible joints, hoses and seals for escaping smoke.
Repair and Retest
Repair the confirmed escape path, repeat the same controlled test, and continue with functional diagnosis if the result is inconclusive or no smoke is visible.
Safety & Compatibility
Keep Test Pressure Within the System Procedure
Match Pressure to the System
The machine rating is not permission to apply its maximum to every vehicle system. Use the OEM or component procedure and the lowest appropriate controlled setting.
Confirm Air and Power
Connect SML310 to a stable DC 12 V / 5 A supply. Its built-in pump provides airflow; do not connect shop air to an unspecified port.
Protect People and Components
Work in a dry, well-ventilated area away from flame and hot sources; use eye and hand protection and avoid directing smoke at smoke-sensitive or precision electronic parts.
Inspect Hoses and Adapters
Do not operate with damaged power leads, hoses or adapters. Clean an opening before inserting an inflatable airbag so sharp edges do not puncture it.
Use Approved Smoke Machine Fluid
Follow the model manual for fluid selection, fill level, draining and storage. Do not use water, viscous or corrosive liquids.
Interpret Results Carefully
Pressure-gauge movement or escaping smoke supports the next inspection step. Neither result alone rules out incorrect isolation, blockage, valve-control, intermittent, or non-leak faults.
Test Results
Read Pressure Movement and Visible Smoke Separately
Read the Hold Result Against the Procedure
Treat the result as a pass only when the selected setup and pressure limit match the vehicle or component procedure.
Pressure Drops or Exceeds the Procedure Limit
Check the machine self-test, connection and intentional openings, then use smoke to inspect for an escape path.
Smoke Escapes
Confirm the smoke is not leaving a normal open route, repair the verified leak and repeat the same test.
No Smoke Is Visible
Recheck setup and isolation, then investigate valve control, blockage, intermittent behavior or a non-leak cause as the vehicle procedure directs.
Compare Models
Compare SML Pressure and Smoke Controls
Model Guide
Choose one or more models. SML310 is selected by default.
| Product Name | SML310 | SML330 | SML400 | SML500 |
|---|---|---|---|---|
| Operating specifications | ||||
| Working Principle | Low Oxygen Combustion | Low Oxygen Combustion | Not stated | Not stated |
| Input Power | DC 12V/5A | DC 12V/5A | DC 12V | Confirm the selected regional power configuration |
| Test Oil Filling Volume | 10ml | 10ml | Not stated | Not stated |
| Rated Output Pressure | <15psi | <15psi | Not stated | Not stated |
| Rated Output Flow | <6L/min | <6L/min | Not stated | Not stated |
| Rated Power | 65W | 65W | Not stated | Not stated |
| High-Temperature Protection | Stops working above 75°C | Stops working above 75°C | Not stated | Not stated |
| LOW-Temperature Protection | Confirm the operating-temperature limit for the selected unit. | Confirm the operating-temperature limit for the selected unit. | Not stated | Not stated |
| Hardware and air supply | ||||
| Flow Meter Window | × | × | Not stated | Not stated |
| Net Weight (Main Unit) | 3.2kg | 3.2kg | Not stated | Not stated |
| Main Unit Dimensions | 250mm*160mm*165mm | 250mm*160mm*165mm | Not stated | Not stated |
| Pressure Gauge | Gauge | Gauge | Not stated | Not stated |
| Air Source Type | Built-in pump | Built-in pump | Built-in pump | Confirm the selected unit’s required air connection |
| Modes and controls | ||||
| Mode Output | Air Mode/Smoke Mode | Air Mode/Smoke Mode | Not stated | Not stated |
| Dual Pressure Mode | × | × | Not stated | Not stated |
| Flow Adjustment Knob | × | √ | Not stated | Not stated |
| Oil Drain Valve | × | × | Not stated | Not stated |
| Fault Indicator Light | × | × | Not stated | Not stated |
| Oil Level Gauge | × | × | Not stated | Not stated |
| Setup & Control | ||||
| Control level | Gauge, Air/Smoke | Gauge + flow adjustment, Air/Smoke | TFT + fixed pressure-hold routine + flow controls | Touchscreen configurable pressure-hold and smoke workflow |
Manual & Downloads
Use the Manual for Setup and Test Pressure
AUTOOL SML310 User Manual
Open the PDF manual for SML310 Air and Smoke modes, pressure checks, built-in pump operation, smoke-oil draining, operating safety, and troubleshooting.

Package
What’s Included
- Confirm Your PackageIncluded accessories can vary by order. Confirm the main unit, 12 V power lead, smoke hose, adapters, sealing tools, oil bottle and quantities before checkout.
FAQs
Air Mode, Oil Drain, and Pressure Questions
What air source does SML310 use?
It has a built-in air pump, so normal testing does not require a separate shop-air compressor.
Can I use the maximum pressure on an EVAP system?
Do not assume so. Choose pressure from the vehicle procedure; machine capacity and EVAP-safe pressure are different facts.
What Does Air Mode Tell Me?
Use Air Mode to observe pressure-gauge behavior under the selected sealed setup. Compare the reading with the vehicle or component limit, then inspect the suspected leak area when the reading changes.
What does Smoke mode add?
Smoke gives a visible tracer for inspecting an escape path after the test volume is connected and isolated correctly.
What if no smoke is visible?
Verify smoke delivery, access, isolation, adapter sealing and valve state. Then continue with the applicable functional diagnosis because blockage, intermittent or non-leak faults may not produce visible smoke.
Are all pictured accessories included?
Package contents vary by order. Confirm every included item and quantity before checkout.
Does a visible leak guarantee the entire repair?
It identifies an area to inspect and confirm. Repair the verified problem and repeat the test, then complete any required vehicle checks.





















No reviews yetBe the first to share your experience with this product.