AUTOOL BT10 電子駐車煞車釋放工具
US$30.00
- Direct EPB Motor Actuation
- Bidirectional Rocker Control
- Approx. One-Second Output
- 10–14 V Service Power
- Direct EPB Motor Actuation: Temporarily release or re-engage a confirmed EPB motor for recovery, vehicle movement, or rear brake service.
- Bidirectional Rocker Control: Drive the connected EPB motor in either direction from the rocker switch.
- Approx. One-Second Output: Limit each apply or release command to about one second of tool output.
- 10–14 V Service Power: Power the tool from a 10–14 V DC service battery and connect its output lead to confirmed EPB drive terminals.
- Protected Output Circuit: Use reverse-polarity protection, power-on indication, overcurrent control, and a replaceable 5 A fast-blow fuse.
- 3 年保用期 主機保固 3 年,配件保固 1 年
- 90日返回 符合條件的退貨可在 90 天內進行
- 官方店鋪 正品 · 直接支持
AUTOOL BT10 · 10–14 V Direct EPB Motor Tool
Control an EPB Motor for Recovery or Service
Temporarily release or engage a confirmed EPB motor for recovery, vehicle movement, or rear-brake service with the AUTOOL BT10. Bidirectional rocker control drives the motor, while an approximately one-second output stop, overcurrent control, reverse-polarity protection, and a replaceable fuse manage the direct-service circuit.
- Direct EPB Motor Actuation
- Bidirectional Motor Control
- Timed Output Stop
- Protected Output Circuit
- Recovery and Brake Service

主要特色
Pulse the EPB Motor in Either Direction
Release And Braking Control
Use the rocker switch to drive the connected EPB motor in either direction for temporary release or re-engagement after movement or service.
Temporary Emergency Release
If an EPB will not release because of a sensor, control-module, wiring, power, or related system fault, BT10 can directly actuate the motor so a trained operator can temporarily disengage the brake for repair, rescue, or controlled vehicle movement.
One-Second Output Limit
BT10 limits each apply or release command to about one second; use the correct terminal, direction, and vehicle procedure.
Layered Circuit Protection
The BT10 includes reverse-polarity protection, a power-on self-check with green status indication, overcurrent control, and a replaceable 5 A fast-blow fuse. Working current: below 15 A. This is not the replacement fuse rating; do not uprate the fuse.
Direct EPB Terminal Workflow
Operate BT10 from a 10–14 V DC service battery through its clamps, then connect the output interface to the confirmed vehicle-side EPB drive terminals before using the rocker switch.
Lower-Force Service Route
Direct controlled actuation can avoid dragging a vehicle with the brake applied or forcing apart brake components during rear brake work.
No Diagnostic Functions
Provides direct bidirectional EPB-motor actuation for the confirmed service connection; diagnosis of the sensor, wiring, module, motor, and stored faults remains a separate scanner and circuit-testing task.
Fault Inspection and Repair
If a sensor failure, control module malfunction, wiring harness fault, or other defect prevents the EPB from releasing, technicians can use the BT10 to disengage the brake during inspection and repair.
Locked Vehicle Relocation
When an EPB locks up after an unexpected incident, the tool can quickly release the brake so the vehicle can be moved, helping prevent tire damage caused by forced dragging.
When an electronic handbrake locks because of power or circuit failure, the BT10 helps release the brake so the vehicle can be relocated in a workshop or dealership.
Brake Service Release
When servicing brake calipers, replacing rear brake pads, or maintaining the brake wheel cylinder, the EPB reset tool helps release the brake and avoid forced disassembly damage.
3年保固支持
主機:三年保固。標準配件:一年保固。保固政策。
如何使用
Set Up, Drive the EPB Motor and Verify
Inspect The Setup
Prepare a fully charged service battery, confirm a 10–14 V DC supply, inspect the built-in fuse, and verify the delivered fuse rating and the page-listed <15 A current field against the exact unit and manual before identifying the correct EPB motor terminals.
Connect Service Power
Connect the red clamp to the positive terminal and the black clamp to the negative terminal. When power is normal, the indicator turns on.
Connect The EPB Motor
With the vehicle secured, connect the EPB terminal interface to the confirmed vehicle-side electronic parking-brake drive terminals before operating the rocker switch.
Pulse Release Or Brake
Use the rocker switch to select braking or release while observing caliper response, then release the switch promptly when the caliper reaches its end position to avoid unnecessary drive force.
Verify And Diagnose
Confirm the brake state and secure the vehicle. Continue with fault-code diagnosis and repair using the appropriate diagnostic route.
安全性和相容性
Use Direct EPB Motor Control Safely
Temporary EPB Actuation
Use BT10 for temporary EPB release or engagement during towing, workshop movement, inspection, or brake service.
Confirm Terminals And Direction
Incorrect terminals or motor direction can move the actuator opposite to the expected action. Stop immediately if response differs.
Use Trained Operation
Secure the vehicle against movement and follow the vehicle service procedure before working on the brake.
Power Conditions
Use only a suitable 10–14 V DC source and correct polarity. Replace the fuse only with the exact type and rating specified for the delivered BT10 and fuse holder; the page-listed 5 A fuse and separate <15 A working-current field are not reconciled.
Connection State
Do not connect or disconnect test equipment with the ignition on or engine running.
Dry Workshop Use
Keep the unit away from water, heat, oil, sharp edges, and moving parts.
Fuse Check
Confirm that the built-in 5A fast-blow fuse is intact before use.
Power-On Self-Check
After powering on, the device performs a system self-check and visually indicates operating status with a green light.
反極性保護
Reverse polarity protection helps reduce device damage risk when the positive and negative terminals are connected incorrectly.
安全儲存條件
Keep the device away from rain, water, damp environments, heat sources, oil, sharp edges, and moving parts.
僅限合格人員
Use only by trained or qualified personnel.
論文規範
Voltage, Current, Timed Output and Fuse Details
| 規格 | 價值 |
|---|---|
| 工作電壓 | 直流 10–14 伏 |
| 工作電流 | Less than 15 A. Confirm the supplied BT10 version for the intended service load before ordering. |
| 自動輸出 | Approximately 1 second per actuation |
| 融合 | 5 A fast-blow. Match the fuse type and rating marked on the supplied unit when replacing it. |
手冊和支持
Confirm EPB Motor Connections, Power and Fuse Requirements

AUTOOL BT10 使用手冊
Open the PDF manual for BT10 EPB motor connection, release control and timed output, with fuse protection, service safety and troubleshooting support.

包裝內容
Check the EPB Release Tool and Included Accessories
- BT10 Main UnitElectronic parking brake release/engagement control unit.
- Battery Clamp LeadRed and black service-power clamps.
- EPB Output LeadDirect connection lead for the confirmed EPB motor terminals.
- 用戶手冊BT10 operating and safety instructions.
常見問題
覆蓋範圍、結果和使用問題
什麼是 AUTOOL BT10 Used For?
AUTOOL BT10 is used to temporarily release or engage an electronic parking brake during EPB system troubleshooting, emergency towing, workshop vehicle movement, brake pad replacement, brake caliper service, and rear brake maintenance.
Is BT10 A Permanent Repair For EPB Problems?
BT10 temporarily releases or engages a compatible EPB for towing, workshop movement, inspection, or brake service; the vehicle fault still requires diagnosis and repair.
What Power Supply Does BT10 Need?
BT10 requires DC 10V-14V power. Prepare a fully charged spare battery before operation and connect the red clamp to positive and the black clamp to negative.
What Is The Difference Between Braking Mode And Release Mode?
Braking mode engages the EPB to support safe parking. Release mode disengages the EPB so the vehicle can be moved during repair, rescue, or maintenance.
What Should I Check Before Operation?
Check that the spare battery is fully charged, confirm the exact fuse type/rating and the page-listed <15 A current field against the delivered unit and manual, connect the red and black battery clamps correctly, and verify the vehicle-side EPB drive terminals.
Why Does The Output Stop After About 1 Second?
BT10 limits each apply or release command to about one second. Use the correct terminal and direction, follow the vehicle procedure, and stop if the actuator binds.
What If The Motor Direction Seems Reversed?
If the switch operation result does not match the expected braking or release action, the motor forward / reverse direction may be reversed. Stop operation and confirm the vehicle-side EPB terminal connection and operating direction before continuing.
What Protection Features Does BT10 Have?
BT10 provides reverse-polarity protection, a power-on self-test indicator, overcurrent control, an approximately one-second output stop, and a 5 A fast-blow fuse. Follow the supplied operating procedure and confirm the correct version for your intended service load.
保固期有多長?
主機:三年保固。標準配件:一年保固。保固政策。
Does BT10 Diagnose EPB Faults?
No. BT10 directly actuates a connected EPB motor. Use a compatible diagnostic tool and the vehicle service procedure to identify sensor, wiring, control-module, motor, or mechanical faults.



















還沒有評論率先分享您使用此產品的體驗。