AUTOOL LM120+ 數位式冷媒歧管壓力表

(53 顧客評價)

US$149.00

☰ 請求批次/B2B報價正式報價請求
  • 3 年保用期 主機保固 3 年,配件保固 1 年
  • 90日返回 符合條件的退貨可在 90 天內進行
  • 官方店鋪 正品 · 直接支持

AUTOOL LM120+ · Dual-Temperature Digital Refrigerant Manifold Gauge

Read Both Sides with Probe-Ready SH/SC

Measure high- and low-side pressure across 0–6 MPa and control refrigerant flow with dedicated valves, a sight window and 1/4-inch fittings. Add compatible wired temperature clamps, sold separately, for T1/T2 readings and superheat/subcooling calculations with the correct refrigerant selected. Relative-vacuum monitoring, timed pressure retention and filling assistance support refrigeration installation and service.

  • 0–6 MPa Gauge Pressure
  • T1/T2 with Optional Clamps
  • Superheat / Subcooling
  • Timed Pressure Retention
  • Sight Window & 1/4-Inch Fittings
AUTOOL LM120+ digital refrigerant manifold gauge for HVAC and refrigeration service

主要特色

Two Temperature Channels Beside High- and Low-Side Pressure

Simultaneous High/Low Pressure

Read high- and low-side pressure during compatible A/C and refrigeration service work.

Dual Temperature Inputs

Displays real-time T1 and T2 temperature readings when compatible clamp-on temperature probes are connected and properly attached to pipes. Display T1/T2 with compatible wired clamps; full contact with the pipe is required.

Superheat And Subcooling

Calculate SH/SC after selecting the correct refrigerant and connecting stable temperature probes.

Relative-Vacuum Mode

Supports relative vacuum measurement, pressure leak measurement, and leak time recording for service checks within the rated range. Monitor pressure during an approved evacuation procedure.

Timed Pressure-Retention Mode

Show initial/current pressure, ΔP and elapsed time for system-tightness assessment.

Charging Assistance

Use the valves, sight window, selected refrigerant data and correctly rated hoses within the equipment-specific procedure.

Built-In Refrigerant Data

The built-in refrigerant database helps reference pressure and evaporation temperature data and supports superheat and subcooling calculations when probes are connected. Shared manual lists 89 refrigerants, but the exact product/version database should be confirmed when a specific gas is critical.

Backlit Multi-Unit Display

The large LCD with backlight improves visibility and makes data easier to read during workshop or field maintenance. Switch among kPa, MPa, bar, inHg and PSI and between Celsius and Fahrenheit.

Durable Handheld Construction

High-strength engineering plastic and flexible non-slip silicone help make the gauge solid, comfortable, and easy to hold. Non-slip engineering-plastic body, long-life valves and standard fittings support workshop use.

儀器重量

The LM120+ instrument weighs 950 g.

3年保固支持

主機:三年保固。標準配件:一年保固。保固政策

如何使用

Connect Both Sides, Clamp Both Lines, and Stabilize

步驟進展1 / 5
01

Identify The Refrigerant

Select the refrigerant confirmed by the vehicle or equipment information before interpreting the LM120+ readings.

安全性和相容性

Confirm Refrigerant, Ports, Hoses, and Limits

Use The Lowest Working Rating

Operate within the lowest working rating of the system, gauge and hose. The standard hose is listed at 600 PSI working pressure.

Inspect Before Pressure Work

Replace damaged hoses, seals and fittings before connection.

Do Not Guess Refrigerant

Select only a refrigerant already identified by reliable system information.

穿戴個人防護裝備並保持通風

Use suitable protection and ventilation and keep the instrument out of hot, humid, flammable, explosive or strong-EMF environments.

Confirm Accessories

Temperature-dependent results require compatible probes; do not promise them when the selected package omits the clips.

No Circuit Modifications

Do not modify the internal circuit, to avoid instrument damage or safety hazards.

Wear Qualified Protection

Wear qualified protective equipment during testing.

確保足夠的通風

Use the instrument in a well-ventilated environment to reduce the risk of inhaling toxic gases.

檢測結果

Interpret Pressure and Dual Temperature Together

Pressure Pair

Compare high- and low-side pressure with the known refrigerant, temperature and equipment procedure to select the next check.

SH And SC

Use only after refrigerant selection and stable pipe-probe contact; bad contact can invalidate the calculation.

Retention ΔP

If retention pressure changes, verify the connections and continue with an approved leak-location method.

Vacuum Trend

Judge against the specific service target and stability period, not a generic elapsed time.

比較型號

Compare Manifold Display and Sensor Options

模型指南

Choose one or more models. LM120+ is selected by default.

已選擇 1 個模型

LM120+ is selected. Choose another model for a side-by-side comparison.

LM120+ comparison

比較您的選擇
選擇適合您任務的選項LM120+
選擇標準
配置重點
Plus kit with three-color hose/probe capability
Probe inclusion
Supported; clamps not included in this configuration

使用者手冊及下載

請使用手冊進行設定和服務

AUTOOL LM120/LM120+ user manual cover
手冊/PDF

AUTOOL LM120+ User Manual

Open the PDF manual for LM120+ dual-pressure readings, temperature probes, superheat and subcooling calculations, charging modes, safe connections, and troubleshooting.

AUTOOL LM120+ package contents

小包裝

產品包括

  • LM120+ Main UnitDigital AC manifold gauge for refrigerant service.
  • Three-Color Hose SetRed, blue and yellow hoses for the plus configuration; confirm ratings and inclusion.
  • Adapters/CouplersConnection hardware; exact items depend on the selected package.
  • 存儲盒保護套。
  • Manual And Retail BoxShared model documentation and packaging.
  • Temperature ClampsCompatible wired test clips are required for temperature and SH/SC functions and are not included in this configuration; confirm before ordering.

常見問題

Dual-Temperature Manifold Questions

Is LM120+ a separate product from LM120?

Yes. Treat it as its own sellable configuration and verify its package rather than merging it into LM120.

Are The Temperature Clamps Included?

No. Compatible temperature clamps are required and sold separately. LM120+ supports dual temperature measurement when the clamp probes are connected to the instrument and fully seated against the refrigeration pipes. Confirm the selected kit before purchase.

Can LM120+ Calculate Superheat And Subcooling?

Yes. The gauge calculates SH superheat and SC subcooling when the correct refrigerant is selected and compatible temperature clamps are connected firmly with full contact on the refrigeration pipes.

How many refrigerants are stored?

The shared manual lists 89, while other page comparison material may differ. Confirm the exact database/version if a specific refrigerant is essential.

它能辨識冷媒嗎?

No. It uses a selected refrigerant database; identification remains a separate task.

Can it locate leaks?

No. Timed pressure retention shows pressure change over the selected period; use an approved method to locate the leak.

What must I confirm about pressure?

Check the system, gauge and hose working ratings separately and use the lowest applicable value.

什麼是 AUTOOL LM120+ Used For?

LM120+ is an auxiliary digital refrigerant manifold gauge for installation, testing, and maintenance of refrigeration equipment such as air conditioners and cold storage systems. It supports dual pressure testing, vacuum measurement, pressure leak testing, refrigerant filling assistance, multi-unit switching, and refrigerant data reference.

  • Four 1.5 V AA/LR6 batteries; confirm whether batteries ship with your package.
When is LM120+ preferable to LM160?

Choose based on required workflow and package. LM160 adds program control and multilingual operation; LM120+ remains a direct handheld manifold configuration.

What Pressure Range Does LM120+ Support?

The instrument measures gauge pressure. The combined warning range is -101kPa to 6MPa, or -0.1bar to 60bar. The pressure test range is 0kPa-6000kPa, the vacuum test range is -101kPa-0kPa, and the instrument overload limit is 10MPa, or 100bar.

What Is The Standard Hose Pressure Limit?

The standard hose maximum operating pressure is 600PSI, approximately 4.13MPa or 41.3bar. The hose limit pressure is 3000PSI, approximately 20.68MPa or 206.8bar. Confirm the tested equipment pressure first, and use suitable replacement hoses if the packed hoses do not match the pressure requirement.

What Batteries Does LM120+ Use?

LM120+ uses 4 × 1.5V AA / LR6 batteries. Prepare batteries separately if your order or shipping region does not include them.

How Many Refrigerants Are Built Into LM120+?

The LM120 / LM120+ manual lists a built-in 89-kind refrigerant NIST database. The comparison chart on the product page may show a different refrigerant species count by model or product version, so confirm the database version with support if this detail is critical for your work.

What Is The Difference Between LM120 And LM120+?

According to the comparison chart, both LM120 and LM120+ support vacuuming mode, refrigerant mode, pressure leak test, foldable hook, visible refrigerant window, and high/low pressure valves. LM120+ additionally shows trichromatic tube support and two wired temperature clamp support.

How Should I Choose Between LM120+, LM150, And LM160?

Choose LM120+ if you need a balanced digital manifold gauge with trichromatic tube, wired temperature clamp support, visible refrigerant window, and high/low valves. Choose LM150 when you need its 93-refrigerant database and two included wired temperature clamps; compare the required probes and functions before ordering. Consider LM160 if you need the higher-end model with program control system, two-side handrails, more language options, and broader database support.

What Should I Check Before Pressure Leak Testing?

Check pipe fittings and hoses before testing. If any damage is found, replace the damaged part immediately to avoid improper use or accidents. Also confirm that the equipment pressure is within the instrument range and that the hose rating is suitable.

Where Can I Download The LM120+ Manual?

Use the Download section on this page to open the AUTOOL LM120 / LM120+ manual PDF. The manual includes cautions, specifications, product structure, refrigerant filling, vacuum operation, pressure leak testing, common problems, maintenance, warranty, and return/exchange information.

保固期有多長?

主機:三年保固。標準配件:一年保固。保固政策

客戶評價

  1. ZH

    Zero Haggai ✓ 已驗證購買 -

    It's decent .

    It’s decent . You can recalibrate and zero out the pressure but you could have pressure in your lines still. Temperature sensors are good but would work better if the clamps had a copper insert for the sensor that covered the surface area of the hoses toy clamp to. I’m gonna make some new clamps with my 3d printer and add space for thermal conducting material in the clamp so the sensor gets a more accurate reading. But still it’s decent for the cost.

    0 of 0 覺得這篇評論很有幫助
  2. VA

    Vivian Archibald ✓ 已驗證購買 -

    These gauges work great they are pretty accurate and will recommend to others great value thank you

    0 of 0 覺得這篇評論很有幫助
  3. RW

    Renata Wyat(t) ✓ 已驗證購買 -

    完美

    Give your freedom of thermostats and tapes around the pipes to check for super heat and sub cooling, it’s just great.recommend 100%

    0 of 0 覺得這篇評論很有幫助
留言

您的電子郵件地址不會被公開。帶*號的為必填項。

LM120+ 冷媒壓力表 數位暖通空調壓力表
AUTOOL LM120+ 數位式冷媒歧管壓力表

US$149.00

瀏覽選擇 該產品有多種變體。可以在產品頁面上選擇這些選項 正式報價請求
享受額外折扣