AUTOOLautoolstore.com
資源: https://autoolstore.com/product/autool-lm100-refrigerant-leak-detector/

AUTOOL LM100 Digital Vacuum Gauge

US$120.00

☰ 請求批次/B2B報價正式報價請求
  • 3 年保用期 主機保固 3 年,配件保固 1 年
  • 90日返回 符合條件的退貨可在 90 天內進行
  • 官方店鋪 正品 · 直接支持

AUTOOL LM100 · Compact Digital Vacuum Gauge

Track Evacuation and Verify Vacuum Hold

Monitor refrigeration-system evacuation and vacuum hold with this digital vacuum gauge. Measure 0–2000 mbar / 0–1500 Torr with ±0.2% full-scale vacuum accuracy and resolution down to 0.1 mbar. The 2.8-inch backlit display presents vacuum and temperature readings in selectable units, while the communication interface shares synchronized measurement data with a separate LM130.

  • 0–2000 mbar Vacuum Range
  • ±0.2% FS Vacuum Accuracy
  • Vacuum-Hold Monitoring
  • 2.8-Inch Backlit Readings
  • LM130 Data Connection
AUTOOL LM100 smart digital vacuum gauge main product image

主要特色

Fine Vacuum Readings with Retention Timing

High-Precision Vacuum and Temperature Measurement

Measure vacuum from 0 to 2000 mbar / 0 to 1500 Torr with resolution of 0.1 hPa, 0.1 mbar, 0.1 Torr, or 0.01 inHg depending on the selected unit. Vacuum measurement accuracy is ±0.2% of full scale, with temperature accuracy up to ±0.5°C / ±0.9°F / ±0.5 K.

Evacuation Monitoring

Follow vacuum level changes while a refrigeration system is being evacuated instead of relying on elapsed pump time alone.

Pressure-Retention Test

Observe pressure changes after system isolation to assess whether sealing needs further investigation.

LM130 Data Transfer

Connect the LM100 to the separate AUTOOL LM130 through the built-in communication interface for synchronized measurement data.

Seven Selectable Units

Switch among hPa, mbar, Torr, inHg, °C, °F and K from the instrument rather than converting readings off-device.

Backlit Fast-Response Display

The 2.8-inch backlit screen responds in about 0.5 seconds for readable monitoring in bright or dim service areas.

Field-Friendly Housing

High-strength engineering plastic, non-slip silicone sides, a brass valve body and a foldable hook support handheld or hanging use.

自動關機

The gauge turns off after 20 minutes without operation to preserve battery power.

3年保固支持

主機:三年保固。標準配件:一年保固。保固政策

如何使用

Evacuate, Isolate, Watch, and Record

步驟進展1 / 5
01

Confirm The Test Limits

Check the equipment rating, the LM100 measuring range and the working-pressure rating of the hose before connection.

安全性和相容性

Protect the Gauge from Pressure and Refrigerant

Respect The Measuring Range

Gauge-pressure measuring range: -101 kPa to 6 MPa (approximately -1.01 to 60 bar). Keep operation within this range; 10 MPa / 100 bar is the absolute limit, not an operating target.

Check Hose Ratings Separately

Standard hose working pressure: 600 PSI / approximately 4.13 MPa / 41.3 bar. Its 3000 PSI / approximately 20.68 MPa / 206.8 bar limit is not a working-pressure rating; use a suitably rated replacement when required.

Use PPE And Ventilation

Wear suitable protective equipment and work in a well-ventilated area when servicing pressurized refrigerant systems.

避免危險環境

Do not use or store the instrument in high heat, high humidity, flammable or explosive areas, or strong electromagnetic fields; do not modify its circuitry.

Choose the Right A/C Tool

Use LM100 for vacuum monitoring and pressure-retention checks. Refrigerant identification, charging and leak location require the appropriate service tools.

檢測結果

Read Vacuum Depth and Retention Together

A Falling Vacuum Reading During Evacuation

Shows the system pressure is being reduced; judge completion against the equipment or service procedure, not a universal time target.

A Stable Isolated Reading

Compare the stabilized isolated reading with the specified hold period, then inspect connections or continue with an approved leak check if pressure changes.

A Changing Isolated Reading

Can indicate a connection, hose or system-sealing problem. Recheck the setup and use an approved method to locate the cause.

Repeatability Matters

Use the same connection, units, stabilization period and environmental conditions when comparing repeat tests.

比較型號

Choose a Vacuum or Manifold Tool

模型指南

選擇一個或多個型號。預設選擇LM100。

已選擇 1 個模型

已選擇LM100。請選擇其他型號進行並排比較。

LM100 對比

比較您的選擇
選擇適合您任務的選項LM100
選擇標準
主要任務
Vacuum and pressure-retention measurement
Refrigerant charging valves
沒有
LM130 synchronized link
支持

使用者手冊及下載

請使用手冊進行設定和服務

AUTOOL LM100 user manual preview
手冊/PDF

AUTOOL LM100 使用手冊

Open the PDF manual for LM100 vacuum measurement, unit selection, evacuation monitoring, LM130 data transfer, safe setup, maintenance, and troubleshooting.

AUTOOL LM100 裝箱清單和包裝內容

小包裝

產品包括

  • LM100 主機AUTOOL LM100 smart digital vacuum gauge.
  • 用戶手冊Printed documentation.
  • 連接電纜Data/connection cable.
  • 黃銅接頭Brass valve connector.
  • Yellow Short HoseShort yellow hose; confirm its rating and inclusion for the selected package.
  • 零售包裝Product box.

常見問題

Vacuum Gauge Setup Questions

How does LM100 support an AC system vacuum test?

LM100 is used for refrigeration, HVAC, and automotive A/C system vacuum monitoring and pressure-retention testing. It helps users observe vacuum-level changes and evaluate refrigeration-system sealing condition.

Does LM100 support refrigerant mode?

No. LM100 is a smart digital vacuum gauge and pressure-retention test tool, not a complete refrigerant manifold gauge. It has no refrigerant database or high/low manifold valves; compare LM120, LM150, or LM160 when those functions are required.

Can it locate a leak?

A pressure change directs the next inspection. Check the setup, then use an approved method to locate the leak.

What units can LM100 switch between?

LM100 supports one-button switching between hPa, mbar, Torr, inHg, °C, °F, and K.

Can LM100 connect to LM130?

Yes. LM100 has an integrated microprocessor and communication interface that connects to LM130 for synchronized high-precision data transmission.

What pressure limit should I watch before testing?
  • LM100 measuring range: -101 kPa to 6 MPa (approximately -1.01 to 60 bar).
  • LM100 measuring range: -101 kPa to 6 MPa; absolute limit: 10 MPa / 100 bar. The absolute limit is not an operating target.
  • Standard hose: 600 PSI / 4.13 MPa / 41.3 bar working pressure; 3000 PSI / 20.68 MPa / 206.8 bar limit.

Use the lowest working rating of the system, gauge, and hose.

Does LM100 automatically power off?

Yes. LM100 automatically powers off after 20 minutes of inactivity to save energy.

下單前我需要確認哪些資訊?

Confirm the required measurement range and units, hose/connector rating, included accessories and whether you also need charging valves, refrigerant data or temperature probes.

What is the LM100 vacuum range?

The vacuum range is 0–2000 mbar / 0–1500 Torr. Vacuum resolution is 0.1 hPa, 0.1 mbar, 0.1 Torr, or 0.01 inHg depending on the selected unit.

包裹中包含什麼?

The package includes the LM100 main unit, product box, user manual, data/connection cable, and brass valve connector. Confirm whether the selected package includes the yellow short hose or any additional accessories, and check the hose rating.

客戶評價

還沒有評論率先分享您使用此產品的體驗。

留言

您的電子郵件地址不會被公開。帶*號的為必填項。

AUTOOL LM100 Digital Vacuum Gauge
AUTOOL LM100 Digital Vacuum Gauge

US$120.00

瀏覽選擇 該產品有多種變體。可以在產品頁面上選擇這些選項 正式報價請求
享受額外折扣