AUTOOL TR401 Digital Anemometer
US$29.00
- 0–30 m/s Air Speed
- 10°C to 45°C Temperature
- Five Air-Speed Units
- Max / Min + Data Hold
- 0–30 m/s Air Speed: Measure local air speed from 0 to 30 m/s with 0.1 m/s displayed resolution.
- -10°C to 45°C Temperature: Read local air temperature from -10°C to 45°C at vents, fans, or outdoor points.
- Five Air-Speed Units: Switch among m/s, mph, km/h, ft/min, and knots, with °C or °F temperature display.
- Max / Min + Data Hold: Track the highest or lowest observed value and freeze a current reading for recording.
- Beaufort + Wind-Chill: View Beaufort force level 0–12 and receive a wind-chill warning below 0 °C when air speed exceeds 5 m/s.
- 3-Yıl Garanti Ana ünite 3 yıl · Aksesuarlar 1 yıl
- 90 Günü İadesi 90 gün içinde iade edilebilir.
- Resmi Mağaza Orijinal ürünler · Doğrudan destek
AUTOOL TR401 · 0–30 m/s Digital Vane Anemometer & Thermometer
Compare Airflow at the Same Vent and Setting
Compare local air speed and temperature at automotive vents, fans, and suitable outdoor or ventilation points with the AUTOOL TR401. The 0–30 m/s meter adds Max/Min tracking, Data Hold, five air-speed units, Beaufort indication, wind-chill warning, and a backlit display for repeated readings.
- 0–30 m/s Air-Speed Range
- −10 to 45 °C Air Temperature
- 0.1 m/s Displayed Resolution
- Max / Min + Data Hold
- Five Air-Speed Units

Ana Özellikler
Capture Air Speed, Temperature, Max and Min
Vane Air-Speed Sensing
The wind wheel measures local air speed from 0 to 30m/s with 0.1m/s displayed resolution and air temperature from -10°C to 45°C.
Local Air-Speed Checks
Use local air-speed readings for basic fan checks during product inspection or comparison.
Air-Temperature Reading
Read local air temperature from -10 to 45 °C at the meter during vent, fan, or outdoor checks.
Five Air-Speed Units
Switch among m/s, mph, km/h, ft/min, and knots; long-press the unit key to change °C and °F.
Max, Min, And Data Hold
Track the highest or lowest observed value and freeze a current reading for recording.
1.6 İnç Arkadan Aydınlatmalı Ekran
Read air speed, temperature, units, and function indicators on the 1.6 in display.
Use the selectable backlight for dim workshop, vent, or outdoor measurement points.
Beaufort And Wind Chill
Display Beaufort force level 0–12 alongside the local air-speed reading.
The wind-chill warning appears when temperature is below 0 °C and air speed exceeds 5 m/s.
Five-Minute Auto-Off
Automatic shutdown after about five minutes without key input conserves battery power.
Task-Specific Measurement
Measures local air speed and temperature at the vane for vent, fan, outdoor, and marine spot checks within the stated ranges; it does not measure humidity, pressure, refrigerant leakage, sound, illuminance, or electrical values.
Marine Wind Checks
Measure local wind speed in marine and boating environments when conditions are within the device rating.
Site and Equipment Checks
Use as a portable wind speed meter for basic reference checks at a site or on equipment.
Automotive and Outdoor Checks
Use the handheld meter for automotive air-conditioning outlets, ventilation checks, outdoor airflow and marine applications within its measurement range.
Ölçüm Fonksiyonları
TR401 keeps air-speed and temperature measurement simple with a sensitive wind wheel sensor, clear display, multiple units, quick reading refresh, automatic shut-off, wind chill warning, and Beaufort wind force reference.
3 Yıl Garanti Desteği
Ana ünite: 3 yıl garanti. Standart aksesuarlar: 1 yıl garanti. Garanti Politikası.
Nasıl Kullanılır?
Hold Conditions Steady, Then Compare Air Speed
Define The Comparison
Choose the vent or point, measurement position, units, blower/fan setting, vehicle state, and ambient condition to keep consistent.
Prepare The Meter
Install three AAA alkaline batteries, power on, select units, and choose live, Max, or Min mode.
Align The Wind Wheel
Face the vane into the local airflow without blocking the opening or changing its distance and angle between readings.
Stabilize and Record the Readings
Let the value stabilize, use Hold if needed, and record speed, temperature, location, time, and operating conditions.
Repeat Before Concluding
Compare several readings under the same conditions and use the relevant A/C, ventilation, or equipment procedure for diagnosis or acceptance.
Güvenlik ve Uyumluluk
Use Local Air Speed as One Test Point
Yerel Hızlı Okuma
TR401 samples air speed at the vane. Total flow requires suitable cross-sectional area and a defined traverse/calculation method.
Use Airflow and Temperature Trends
Use outlet speed and temperature to document airflow and temperature changes during A/C checks, then follow the appropriate system test for the suspected fault.
Derecelendirilmiş Ortam
Use the device within the specified environment: -10°C~45°C and humidity ≤80%RH.
Avoid Hazardous Areas
Do not use or store in flammable, explosive, high-temperature, or high-humidity environments.
Avoid Strong Interference
Keep the device away from strong electromagnetic radiation during use and storage to reduce measurement interference.
Protect The Vane
Keep the wind wheel clean and unobstructed; do not force or strike it.
akü Depolama
Replace batteries when the low-battery icon appears and remove them for extended storage.
Bakım ve Bakım
Unauthorized disassembly is not recommended and may affect safe operation or warranty support.
Bakım ve Güvenlik Notları
Avoid corrosive chemicals. If exterior cleaning is needed, use a neutral cleaning agent.
Sonuçlar
Compare Air-Speed Readings Under Consistent Conditions
Vent-To-Vent Comparison
Measure comparable vents at the same blower setting, vane position, and vehicle condition to locate a repeatable imbalance.
Before-And-After Check
Repeat the same test after service or adjustment; record both the numeric change and unchanged environmental conditions.
Değişken Hava Akışı
Use Max/Min with a defined observation period to capture changes, then investigate the control or system that may cause them.
Açık Hava Okuma
Use Beaufort and wind-chill displays as local references within the meter range, not as a certified weather or safety report.
Özellikler
Speed Range, Units and Environment
| Özellikler | Özellik |
|---|---|
| Air-Speed Range | 0-30 m/sn |
| Air-Speed Resolution | (0.1 m/s hız) |
| Air-Speed Units | m/s, mph, km/h, ft/min, knots |
| Sıcaklık aralığı | -10 ile 45 ° C |
| Sıcaklık Birimleri | °C / °F |
| Örnekleme Aralığı | 0.5 s |
| Beaufort Display | 0-12 |
| Wind-Chill Trigger | Below 0 °C and above 5 m/s |
| Çalışma Nemi | ≤% 80 Bağıl Nem |
| ekran | 1.6-inch backlit |
| Power | 3 × 1.5 V AAA alkaline batteries |
| Otomatik kapalı | Approximately 5 minutes without key input |
Kılavuz ve Destek
Confirm the Measurement Setup

AUTOOL TR401 Kullanım Kılavuzu
Open the PDF manual for TR401 air-speed measurement, temperature readings and vent comparison, with unit-selection guidance, operating safety and troubleshooting support.

Paket İçeriği
Check the Meter and Included Accessories
- TR401 AnemometerHandheld vane air-speed and temperature meter.
- AAA PillerThree 1.5 V alkaline batteries.
- Bilek KayışıHand strap for portable use.
- Kullanım kılavuzuOperating and maintenance instructions.
- Perakende kutusuTR401 product packaging.
SSS
Air-Speed and Temperature Questions
Ne yapabilirim AUTOOL TR401 Measure?
TR401 measures wind speed, air temperature, Beaufort wind force level, and wind chill warning conditions. It is suitable for airflow and temperature checks such as automotive AC outlets, ventilation systems, outdoor use, fan manufacturing, maritime operations, and wind energy applications.
TR401 measures local air speed and air temperature at its wind wheel, displays a Beaufort level, and provides a wind-chill warning under its trigger conditions. It does not directly calculate duct volume flow or diagnose an automotive A/C fault.
Which Wind Speed And Temperature Units Does TR401 Support?
TR401 supports wind speed units m/s, mph, km/h, ft/min, and knots. It supports temperature units °C and °F. Press the Unit key to switch wind speed units, and long press the Unit key to switch temperature units.
What Batteries Does TR401 Use?
TR401 uses 3 AAA 1.5V alkaline batteries. Insert the batteries according to the positive and negative marks inside the battery compartment. Replace them promptly when the low-battery icon appears, and remove the batteries before long-term storage.
When Does The Wind Chill Warning Appear?
The Wind Chill warning appears when the temperature is below 0°C and the wind speed is greater than 5m/s. When the WINDCHILL signal appears, pay attention to low-temperature and high-wind conditions.
How Do I Use Backlight, Data Hold, And Max/Min Mode?
- Press the power/backlight key during operation to turn the backlight on or off.
- Press the Data Hold key to lock or unlock the current displayed reading.
- Press the measurement mode key to switch among real-time, Max, and Min reading modes.
Does TR401 Turn Off Automatically?
Yes. During normal operation, TR401 automatically turns off after approximately 5 minutes of no key operation to save power. Auto power-off can be disabled from the power-off state by using the key combination described in the user manual.
Can TR401 Measure Light, Sound, Humidity, Or Pressure?
No. TR401 is designed for wind speed and temperature measurement. For illuminance, choose TE301. For sound level, choose TN201. For temperature and humidity, choose TM101. TR401 is not a pressure tester or refrigerant leak detector.
What Is Included In The TR401 Package?
The TR401 package includes the digital anemometer main unit, three AAA batteries, wrist strap, retail box, and user manual.
Garanti süresi ne kadar?
Ana ünite: 3 yıl garanti. Standart aksesuarlar: 1 yıl garanti. Garanti Politikası.
Does TR401 Measure Air Volume Or CFM?
No direct duct-volume or CFM calculation is specified. TR401 measures local air speed in m/s, mph, km/h, ft/min, or knots. Converting speed to volume flow requires a suitable area and traverse method.
Can One Vent Reading Diagnose An A/C Problem?
No. Record vent, blower setting, vehicle state, ambient condition, measurement position, and repeated readings. Air speed and outlet-air temperature can show a repeatable symptom, while refrigerant charge, compressor, controls, doors, leaks, and other causes require the matching service procedure and tools.























Henüz değerlendirme yokBu ürünle ilgili deneyimlerinizi ilk paylaşan siz olun.