AUTOOLotoolstore.com
Kaynak: https://autoolstore.com/product/autool-lm160-refrigerant-leak-detector-digital-manifold-gauges/

AUTOOL LM160 Smart Digital Manifold Kit

(4 Müşteri yorumları)

US$209.00

  • 3-Yıl Garanti Ana ünite 3 yıl · Aksesuarlar 1 yıl
  • 90 Günü İadesi 90 gün içinde iade edilebilir.
  • Resmi Mağaza Orijinal ürünler · Doğrudan destek

AUTOOL LM160 · Program-Controlled AC Manifold Gauge

Guide Refrigerant Service from One Interface

Use guided menus to measure refrigeration-system pressure across 0–60 bar and temperature with compatible probes, monitor relative vacuum, and review timed pressure-retention results. Select from 95 refrigerant profiles and eight interface languages, with switchable pressure, vacuum and temperature units. The 2.8-inch backlit display, high/low valves and sight window keep readings and flow control together.

  • 0–60 bar Gauge Pressure
  • 95 Refrigerant Profiles
  • 8 Interface Languages
  • Guided Test Menus
  • Timed Pressure Retention
AUTOOL LM160 smart digital manifold kit main product image

Ana Özellikler

Programmed Controls with a 95-Refrigerant Library

Program-Controlled Workflow

Choose test modes and review detailed results through guided menus, keeping setup and measurement review in one interface.

95-Refrigerant Database

The internal refrigerant database covers 95 standard refrigerants, including examples such as R134a, R22, H2O, R401C, and 1234zeE.

Live Pressure And Temperature

Displays real-time refrigeration-system gauge pressure and temperature readings with correctly connected probes.

Vakum İzleme

Follow pressure and elapsed time during an approved evacuation procedure.

Timed Pressure-Retention Results

Track starting pressure, current pressure and ΔP to assess system tightness, then use an approved leak-location method if the pressure changes.

Eight Languages

Supports pressure, temperature, and vacuum unit switching, plus English, French, German, Italian, Spanish, Portuguese, Chinese, and Japanese.

Choose Your Units

Choose pressure, vacuum and temperature units to suit your service procedure.

Pressure Unit Options

Read pressure in psi, kPa, MPa, bar or kg·cm⁻² to match the service specification.

Vacuum Unit Options

Select Micron, hPa, mbar, mTorr or Torr for vacuum readings.

Sıcaklık Birimi Seçenekleri

Display temperature in °C or °F to match the service procedure.

Backlit Responsive Display

Read changing measurements on the 2.8-inch backlit screen, with updates in about 0.5 seconds, including in darker work areas.

Complete Control Hardware

High- and low-pressure valves, a refrigerant sight window, foldable hook, and two side handles support service-bay operation and handling.

Two Clamp And Hose Kit

The selected kit includes two wired temperature clamps, three-color hoses, and red/blue couplers or adapters; confirm the selected package.

3 Yıl Garanti Desteği

Ana ünite: 3 yıl garanti. Standart aksesuarlar: 1 yıl garanti. Garanti Politikası.

Nasıl Kullanılır?

Connect, Select the Program, Stabilize, and Review

Adım ilerleme1 / 5
01

Confirm Refrigerant And Procedure

Identify the refrigerant independently, verify it appears in the database and review the equipment instructions.

Güvenlik ve Uyumluluk

Confirm Refrigerant, Service Ports, and Limits

Assess System Tightness

Assess system tightness from pressure change, then use an approved leak-location method when the result calls for inspection.

Stay Within Working Ratings

Normal coverage is up to 6 MPa / 60 bar and about -101 kPa vacuum; the 10 MPa device maximum and 3000 PSI hose maximum are not working targets.

Confirm Hose Suitability

The standard hose working rating is 600 PSI; substitute a properly rated hose when required.

Use PPE And Ventilation

Wear protection and ventilate the area; avoid heat, humidity, flammable/explosive areas and strong electromagnetic fields.

Do Not Modify Circuitry

Use the current manual and do not alter internal electronics.

Wear Approved Protection

Wear approved protective equipment during testing to protect the user.

Yeterli Havalandırmayı Sağlayın

Use LM160 in a well-ventilated environment to help prevent inhalation of toxic gases.

Verify Test Requirements

Confirm refrigerant, pressure, hose, and connection requirements before starting a test.

Maximum Device Pressure

The maximum device pressure / overload limit is 10 MPa / 100 bar. This is not the normal measuring range and does not permit exceeding the rated pressure of the tested system.

Test Sonuçları

Use Guided Pressure and Temperature Checks for A/C Diagnosis

Live Refrigeration Values

Compare pressure and temperature with the known refrigerant and operating condition to select the next A/C check.

Pressure-Retention ΔP

If ΔP changes, verify the connections and continue with an approved leak-location method.

Vakum Durumu

Compare the achieved level and stability with the service specification.

Use the Guided Readings

Program control guides measurement setup and result display. Select the known refrigerant and compare readings with the equipment procedure.

Modelleri Karşılaştır

Compare Refrigerant Coverage and Controls

Model Rehberi

Bir veya daha fazla model seçin. LM160 varsayılan olarak seçilidir.

1 model seçildi

LM160 seçildi. Yan yana karşılaştırma için başka bir model seçin.

LM160 karşılaştırması

Seçeneklerinizi Karşılaştırın
Göreviniz İçin Seçim YapınLM160
Seçim Kriterleri
Başlıca farklılaştırıcı özellik
Program control, 95 refrigerants, 8 languages
Leak-point location
Yok hayır
SH/SC support
Sipariş vermeden önce onaylayın.

Kullanım Kılavuzu ve İndirmeler

Kurulum ve Servis İçin Kullanım Kılavuzunu Kullanın

AUTOOL LM160 kullanım kılavuzu kapağı
Kullanım Kılavuzu / PDF

AUTOOL LM160 Kullanıcı Kılavuzu

Open the PDF manual for LM160 guided menus, refrigerant selection, pressure and temperature readings, vacuum and retention tests, safe operation, and troubleshooting.

AUTOOL LM160 packing list with main unit storage case hoses temperature clamps adapters manual retail box and accessories

paket

Neler Dahil?

  • LM160 Main UnitSmart digital manifold kit.
  • Sert Saklama KutusuKoruyucu kılıf.
  • Three-Color HosesService hose set; verify working rating for the application.
  • Two Wired Temperature ClampsPipe probes.
  • Red/Blue Couplers Or AdaptersConnection pieces; confirm the exact selected-package pieces.
  • Manual And Retail BoxDocumentation and packaging.

SSS

Program, Refrigerant, and Connection Questions

Is LM160 a refrigerant sniffer?

No. Pressure-retention mode assesses system tightness from pressure change. Use a refrigerant detector or another approved method to locate a leak.

Does it identify refrigerant?

No. Select only refrigerant already identified from reliable system information.

How many refrigerants are listed?

95 selectable profiles.

Which Units And Languages Are Supported?
  • Pressure units include psi, kPa, MPa, bar, and kg/cm²;
  • temperature units include °F and °C;
  • vacuum units include Micron, hPa, mbar, mTorr, and Torr.

The interface supports English, French, German, Italian, Spanish, Portuguese, Chinese, and Japanese.

Which modes are available?

Live refrigeration readings, vacuum monitoring and timed pressure-retention testing.

What pressure figures govern use?

Stay within the measuring range and the lowest working rating among system, gauge and hose; do not use maximum/limit figures as targets.

Are temperature clamps included?

The selected kit includes two wired clamps; confirm their inclusion before ordering.

Should I choose LM160 for SH/SC?

If subcooling or superheat calculation is required, confirm that function for the selected LM160 package before ordering; LM70 is listed with SH/SC support.

What does program control change?

It guides mode selection and result display; the technician selects the refrigerant, verifies connections and ratings, and applies the service criteria.

Zirkonyum Tedavisi AUTOOL LM160 Used For?

LM160 is a smart digital manifold kit used for refrigeration and A/C system pressure leak testing, vacuuming mode monitoring, and refrigerant mode data measurement. It is designed to help simplify traditional manifold gauge operation with intelligent program control and clear on-screen data.

What Does Gauge Pressure Mean On LM160?

Pressure measured with a digital manifold pressure tester is gauge pressure. Always compare the LM160 reading with the rated pressure and test requirements of the device or system being tested.

What Pressure And Vacuum Range Can LM160 Measure?

The specification range is 0-870psi / 0-60bar for relative pressure and -14.7-0psi / -1-0bar for relative vacuum. The warm-tip guidance also describes a pressure test span from about -101kPa to 6MPa. Do not use the device beyond the measuring range or beyond the rated pressure of the system under test.

What Is The Standard Hose Pressure Limit?

The standard hose maximum working pressure is 600 PSI, approximately 4.13MPa / 41.3bar. The standard hose burst pressure is 3000 PSI, approximately 20.68MPa / 206.8bar. If the packaged hose does not meet your test requirement, use a suitable rated alternative.

How Many Refrigerants Does LM160 Support?

LM160 has a built-in database of 95 standard refrigerants, including R134a, R22, H2O, R401C, and 1234zeE.

Which Modes Does LM160 Support?

LM160 supports pressure leak test, vacuuming mode, and refrigeration mode. Pressure leak test checks system tightness, vacuuming mode monitors pressure while drawing a vacuum, and refrigeration mode displays real-time pressure and temperature data.

What Should I Check Before Testing?

Check the rated pressure value of the device under test, confirm that LM160 and the hose are within the required measuring range, use suitable rated hoses when necessary, and confirm that the refrigerant and connection method match the system being tested.

Hangi güvenlik önlemlerini almalıyım?

Do not use or store LM160 in high temperature, high humidity, flammable, explosive, or strong electromagnetic field environments. Do not modify the internal circuitry. Wear approved protective equipment and use the device in a well-ventilated environment to help prevent inhalation of toxic gases.

What Is Included In The LM160 Package?

Package contents include the LM160 main unit, storage case, trichromatic refrigerant hoses, two wired temperature clamps, red and blue adapters or couplers, user manual, and retail box.

How Is LM160 Different From LM120, LM120+, And LM150?

According to the comparison chart, LM160 adds program control, 8 interface languages, a 95-refrigerant database, high/low pressure valves, two wired temperature clamps, a foldable hook, two side handles, and a refrigerant sight window.

Should I Choose LM160 For Subcooling / Superheat Or Dual-Channel Real-Time Pressure Monitoring?

If subcooling/superheat or dual-channel real-time pressure monitoring is required, ask AUTOOL to confirm the suitable model and current package before ordering.

Garanti Süresi Ne Kadardır?

Ana ünite: 3 yıl garanti. Standart aksesuarlar: 1 yıl garanti. Garanti Politikası.

Yorumlar

  1. NM

    Nikolai Marinov ✓ Onaylanmış Satın Alma -

    Ben çok memnunum

    Ben çok memnunum

    0 of 0 bu incelemeyi yararlı buldum
  2. JM

    John Meiner. ✓ Onaylanmış Satın Alma -

    Önerdiklerimiz

    Product is portable, very well designed, replaces freon quickly and works well

    0 of 0 bu incelemeyi yararlı buldum
  3. DM

    Dra?en Mraz ✓ Onaylanmış Satın Alma -

    harika

    0 of 0 bu incelemeyi yararlı buldum
İnceleme bırak

E-posta adresiniz yayınlanmayacaktır. Zorunlu alanlar * ile işaretlenmiştir .

LM160 Refrigerant Leak Detector Digital Manifold Gauges
AUTOOL LM160 Smart Digital Manifold Kit

US$209.00

Ürünü Görüntüle Bu ürünün birden fazla çeşidi bulunmaktadır. Seçenekler ürün sayfasında seçilebilir Resmi Teklif Talebi
Ekstra İndirim Alın