- Dual-Channel Comparison
- 0–210 Bar Range
- 3-Inch Backlit Display
- Lock + Ambient Zero
- Dual-Channel Comparison: Measure two caliper pressure positions together and compare front/rear or left/right pressure behavior for hydraulic imbalance.
- 0–210 Bar Range: Cover 0–210 bar with ±1% FS accuracy and 0.1 display resolution.
- 3-Inch Backlit Display: Read pressure data on the 3-inch screen in bright or dim workshop conditions.
- Lock + Ambient Zero: Hold readings and zero the channels to ambient pressure with one-click controls.
- Dual-Channel Comparison: Measure two caliper pressure positions together and compare front/rear or left/right pressure behavior for hydraulic imbalance.
- 0–210 Bar Range: Cover 0–210 bar with ±1% FS accuracy and 0.1 display resolution.
- 3-Inch Backlit Display: Read pressure data on the 3-inch screen in bright or dim workshop conditions.
- Lock + Ambient Zero: Hold readings and zero the channels to ambient pressure with one-click controls.
- 3-Year Warranty Main unit 3 years · Accessories 1 year
- 90-Day Returns Eligible returns within 90 days
- Official Store Genuine products · Direct support
AUTOOL PT660 · Dual Brake Pressure Tester
Compare Two Brake Pressure Points at Once
Compare hydraulic pressure at two brake positions during the same test condition with this dual-channel brake pressure gauge. PT660 measures both channels across 0–210 bar, helping reveal front/rear or left/right imbalance without moving one gauge between points. Hold and ambient-zero controls support repeatable setup, while the backlit display keeps both readings visible.
- 0–210 Bar Brake Range
- Dual-Channel Brake Comparison
- Stated ±1% FS Accuracy
- Hold Both Channel Readings
- Ambient-Zero Both Channels

Key Features
Synchronous Left/Right Pressure Inputs
Dual-Channel Brake Pressure Detection
Detect two brake pressure channels through the L/R input slots, making it easier to compare front / rear or left / right brake pressure behavior.
Brake Pressure Balance Comparison
Supports simultaneous pressure comparison between two brake calipers, helping technicians capture pressure differences and observe brake-system pressure imbalance.
Stated ±1% FS Accuracy
Built-in high-precision sensor provides measurement accuracy up to ±1%FS for brake system pressure checking.
Wide Measuring Range
PT660 supports a 0–210 bar measurement range with 0.1 resolution and an operating temperature range of -10°C to +60°C, helping cover common internal brake-system pressure checks.
Smart 3-Inch Backlit Display
The 3-inch backlit digital display shows pressure data clearly in bright or dim workshop environments without complicated menu browsing.
One-Click Locking And Zeroing
Supports one-click locking and zeroing, zeroing to ambient pressure, and visualized data display for more efficient brake pressure measurement.
3 Years Warranty Support
Main unit: 3-year warranty. Standard accessories: 1-year warranty. Warranty Policy.
Service Workflow
Connect Both Sides and Compare Like Conditions
Connect L/R Pressure Input
Connect the pressure input cable to the L/R slot according to the channel you need to test or compare.
Zero Before Testing
With both channels safely open to ambient pressure and unloaded, perform the user zero/tare step before connecting and pressurizing the brake system. This is a setup zero, not a traceable calibration.
Install Adapter
Connect the model-specific adapter to the measurement probe and confirm the connection is secure.
Select Unit And Wheel Direction
Select the required unit, such as psi, Bar, or kg/cm², and choose the wheel direction before testing.
Start Measurement
Press the Measurement button to start brake pressure measurement and monitor the pressure values on the display.
Review And Switch Units
After measurement is complete, review the results, compare pressure values, and switch units when needed.
Safe Use
Control Hydraulic Pressure and Bleeding State
Use the Result for the Next Check
Compare both channels under the same pedal condition with brake-fluid-rated hoses and adapters. Investigate the relevant hydraulic circuit if an imbalance appears.
Model Comparison
Choose the Right Pressure Test Kit
Model Guide
Choose one or more models. PT660 is selected by default.
| Product Name | PT610 Cylinder Pressure Gauge | PT620 Oil Pressure Gauge Kit | PT630 Fuel Pressure Gauge | PT635 Fuel Pressure Gauge(High-end version) | PT640 GDI Fuel Pressure Gauge | PT650 Transmission Oil Pressure Gauge | PT660 Brake System Pressure Tester |
|---|---|---|---|---|---|---|---|
| Measurement & Readout | |||||||
| Display Screen | 2.8-inch | 2.8-inch | 2.8-inch | 2.8-inch | 2.8-inch | 2.8-inch | 3-inch |
| Data Storage | 6 Sets of Data | × | × | × | × | × | Locks the current reading; check the current specification for multi-record storage. |
| Pressure Range | 0-426.6psi 0-30kg/cm² 0-29.4bar | 0-426.6psi 0-30kg/cm² 0-29.4bar | 0-426.6psi 0-30kg/cm² 0-29.4bar | 0-426.6psi 0-30kg/cm² 0-29.4bar | 0-5221.3psi 0-367kg/cm² 0-360bar | 0-426.6psi 0-30kg/cm² 0-29.4bar | 0–210 bar |
| Dual-Channel Pressure Testing | × | × | × | × | × | × | Two brake positions/calipers via L/R channels |
| Data Lock/Clear/Record | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Multi-Parameter Display | Current Temp Measurement Time Real-Time Pressure Value Average Pressure Value Pressure value of each cylinder | Measurement Time Pressure Maximum Pressure Minimum Pressure Differential | Maximum Value Minimum Value Differential Pressure Value Measurement Time Real-Time Pressure Value | Maximum Value Minimum Value Average Value Temperature Value Measurement Time Real-Time Pressure Value | Maximum Value Minimum Value Differential Pressure Value Measurement Time Real-Time Pressure Value | Maximum Value Minimum Value Differential Pressure Value Measurement Time Real-Time Pressure Value | Left/right real-time pressure, minimum, maximum, and front/rear pressure difference |
| Pressure Units | Psi Bar Kg/cm² | Psi Bar Kg/cm² | Psi Bar Kg/cm² | Psi Bar Kg/cm² | Psi Bar Kg/cm² | Psi Bar Kg/cm² | psi / bar / kg/cm² |
| Connections & Applications | |||||||
| Accessory Connectors | 10 Types | 18 Types | 17 Types | 31 Types | 3 Types | 12 Types | Check the selected package contents for included adapter types and quantities. |
| Equipped Toolbox | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Applicable Scenarios | Engine Cylinder | Engine Oil Circulation System | Automotive Fuel System | Automotive Fuel System | Fuel Injection Pump Pressure in the Automotive Direct Injection System | Automotive Transmission Pressure | Internal brake-system fluid pressure; two-position/caliper comparison |
Manual & Support
Find the Manual and Adapter Guidance

AUTOOL PT660 User Manual
Open the PDF manual for AUTOOL PT660 dual-channel brake-pressure testing, side-to-side comparison, unit selection, locking and zeroing, safe hydraulic connection and troubleshooting support.

Package Contents
See What Comes in the Box
- Order ScopeConfirm the exact included items for the selected package before ordering.
Buyer Questions
Pressure Connection and Reading Questions
Do I Need To Zero The PT660 Before Testing?
Zero the PT660 to ambient pressure before every test to improve measurement reliability.
What Is The Measurement Range Of PT660?
PT660 supports a measurement range of 0-210Bar. Always pay attention to the measuring range before and during testing.
What Units Does PT660 Support?
PT660 supports psi, Bar, and kg/cm². The resolution is 0.1psi, 0.1Bar, and 0.1kg/cm².
Can PT660 Compare Two Brake Calipers?
Yes. PT660 supports dual-channel pressure measurement and can be used to compare the pressure of two brake calipers or two brake pressure positions through the L/R pressure input channels.
What Batteries Does PT660 Use?
PT660 uses 4 × 1.5V AAA batteries. Check battery level and battery condition before testing.
What Happens If The Measuring Range Is Exceeded?
If the measuring range is exceeded, the result may display the maximum or minimum value. Stop testing, confirm the pressure condition, and make sure the test is within the supported range.
What Should I Check Before Use?
Before use, check the batteries, pressure input cable, hoses, adapters, and all connections. Wear safety goggles and protective gloves when working near brake fluid or system fluid.

























Bob L ✓ Verified Purchase –
Great quality
Have used it on several customer cars. Easy to use and works great!
David ✓ Verified Purchase –
Sehr schöne Maschine.
Die überwachungsdaten sind sehr genau und helfen mir bei meiner Arbeit sehr.
Und sie sind effizient.
David ✓ Verified Purchase –
Sehr schöne Maschine.
Die überwachungsdaten sind sehr genau und helfen mir bei meiner Arbeit sehr.
Und sie sind effizient.