AUTOOL เครื่องวัดสุญญากาศดิจิทัล LM100
US$120.00
- Evacuation & Hold Checks
- Vacuum Range & Accuracy
- 2.8-Inch, 0.5-Second Readout
- LM130 Data Link
- Evacuation & Hold Checks: Follow vacuum changes during evacuation, then observe pressure after isolation to assess whether system sealing needs further investigation.
- Vacuum Range & Accuracy: Measure 0–2000 mbar / 0–1500 Torr with resolution down to 0.1 mbar and ±0.2% full-scale vacuum accuracy.
- 2.8-Inch, 0.5-Second Readout: The 2.8-inch backlit display responds in about 0.5 seconds and switches among seven vacuum or temperature units.
- LM130 Data Link: Connects to the separate LM130 through its built-in communication interface for synchronized measurement data.
- 3- รับประกันปี ตัวเครื่องหลัก 3 ปี · อุปกรณ์เสริม 1 ปี
- 90-Day Returns สินค้าที่ส่งคืนต้องอยู่ในสภาพสมบูรณ์ภายใน 90 วัน
- ร้านค้าอย่างเป็นทางการ สินค้าแท้ · การสนับสนุนโดยตรง
AUTOOL LM100 · Compact Digital Vacuum Gauge
Track Evacuation and Verify Vacuum Hold
Monitor refrigeration-system evacuation and vacuum hold with this digital vacuum gauge. Measure 0–2000 mbar / 0–1500 Torr with ±0.2% full-scale vacuum accuracy and resolution down to 0.1 mbar. The 2.8-inch backlit display presents vacuum and temperature readings in selectable units, while the communication interface shares synchronized measurement data with a separate LM130.
- 0–2000 mbar Vacuum Range
- ±0.2% FS Vacuum Accuracy
- Vacuum-Hold Monitoring
- 2.8-Inch Backlit Readings
- การเชื่อมต่อข้อมูล LM130

Key Features
Fine Vacuum Readings with Retention Timing
High-Precision Vacuum and Temperature Measurement
Measure vacuum from 0 to 2000 mbar / 0 to 1500 Torr with resolution of 0.1 hPa, 0.1 mbar, 0.1 Torr, or 0.01 inHg depending on the selected unit. Vacuum measurement accuracy is ±0.2% of full scale, with temperature accuracy up to ±0.5°C / ±0.9°F / ±0.5 K.
Evacuation Monitoring
Follow vacuum level changes while a refrigeration system is being evacuated instead of relying on elapsed pump time alone.
Pressure-Retention Test
Observe pressure changes after system isolation to assess whether sealing needs further investigation.
LM130 Data Transfer
Connect the LM100 to the separate AUTOOL LM130 through the built-in communication interface for synchronized measurement data.
Seven Selectable Units
Switch among hPa, mbar, Torr, inHg, °C, °F and K from the instrument rather than converting readings off-device.
จอแสดงผลแบบมีไฟแบ็คไลท์ตอบสนองเร็ว
The 2.8-inch backlit screen responds in about 0.5 seconds for readable monitoring in bright or dim service areas.
Field-Friendly Housing
High-strength engineering plastic, non-slip silicone sides, a brass valve body and a foldable hook support handheld or hanging use.
ปิดเครื่องอัตโนมัติ
The gauge turns off after 20 minutes without operation to preserve battery power.
รับประกัน 3 ปี
ตัวเครื่องหลัก: รับประกัน 3 ปี อุปกรณ์เสริมมาตรฐาน: รับประกัน 1 ปีนโยบายการรับประกัน
วิธีใช้
Evacuate, Isolate, Watch, and Record
Confirm The Test Limits
Check the equipment rating, the LM100 measuring range and the working-pressure rating of the hose before connection.
Connect And Select Units
Use a suitable rated hose, position the gauge with the foldable hook if useful, and choose the vacuum or temperature unit required by the procedure.
Monitor Evacuation
Run the approved evacuation procedure and follow the live vacuum trend until the service specification is reached.
Isolate And Observe
Close the system as required, use pressure-retention mode and observe the change over the specified test period.
Interpret And Follow Up
Compare the result with the equipment maker’s procedure. If pressure changes, inspect connections and continue with an approved leak-location method before charging.
ความปลอดภัยและความเข้ากันได้
Protect the Gauge from Pressure and Refrigerant
Respect The Measuring Range
Gauge-pressure measuring range: -101 kPa to 6 MPa (approximately -1.01 to 60 bar). Keep operation within this range; 10 MPa / 100 bar is the absolute limit, not an operating target.
Check Hose Ratings Separately
Standard hose working pressure: 600 PSI / approximately 4.13 MPa / 41.3 bar. Its 3000 PSI / approximately 20.68 MPa / 206.8 bar limit is not a working-pressure rating; use a suitably rated replacement when required.
ใช้ชุดอุปกรณ์ป้องกันส่วนบุคคล (PPE) และระบบระบายอากาศ
Wear suitable protective equipment and work in a well-ventilated area when servicing pressurized refrigerant systems.
หลีกเลี่ยงสภาพแวดล้อมที่เป็นอันตราย
Do not use or store the instrument in high heat, high humidity, flammable or explosive areas, or strong electromagnetic fields; do not modify its circuitry.
Choose the Right A/C Tool
Use LM100 for vacuum monitoring and pressure-retention checks. Refrigerant identification, charging and leak location require the appropriate service tools.
ผลการทดสอบ
Read Vacuum Depth and Retention Together
A Falling Vacuum Reading During Evacuation
Shows the system pressure is being reduced; judge completion against the equipment or service procedure, not a universal time target.
A Stable Isolated Reading
Compare the stabilized isolated reading with the specified hold period, then inspect connections or continue with an approved leak check if pressure changes.
A Changing Isolated Reading
Can indicate a connection, hose or system-sealing problem. Recheck the setup and use an approved method to locate the cause.
Repeatability Matters
Use the same connection, units, stabilization period and environmental conditions when comparing repeat tests.
เปรียบเทียบรุ่น
Choose a Vacuum or Manifold Tool
คู่มือรุ่น
เลือกโมเดลอย่างน้อยหนึ่งรุ่น โดยค่าเริ่มต้นจะเลือก LM100 ไว้แล้ว
| เลือกให้เหมาะสมกับงานของคุณ | LM100 | LM70 | LM120 | LM130 | LM150 | LM160 |
|---|---|---|---|---|---|---|
| เกณฑ์การคัดเลือก | ||||||
| งานหลัก | Vacuum and pressure-retention measurement | Dual-pressure manifold with superheat/subcooling | Digital manifold service | Smart manifold kit with LM100 link | Digital manifold with wired clamps | Program-controlled multilingual manifold |
| Refrigerant charging valves | ไม่ | มี (ใบกำกับภาษีเต็มรูปแบบ) | มี (ใบกำกับภาษีเต็มรูปแบบ) | โปรดยืนยันก่อนสั่งซื้อ | มี (ใบกำกับภาษีเต็มรูปแบบ) | มี (ใบกำกับภาษีเต็มรูปแบบ) |
| LM130 synchronized link | ที่สนับสนุน | ไม่ระบุ | ไม่ระบุ | Host device | ไม่ระบุ | ไม่ระบุ |
คู่มือและไฟล์ดาวน์โหลด
โปรดใช้คู่มือในการติดตั้งและบำรุงรักษา

AUTOOL คู่มือผู้ใช้ LM100
Open the PDF manual for LM100 vacuum measurement, unit selection, evacuation monitoring, LM130 data transfer, safe setup, maintenance, and troubleshooting.

แพ็คเกจ
มีอะไรบ้าง
- ยูนิตหลัก LM100AUTOOL LM100 smart digital vacuum gauge.
- คู่มือการใช้Printed documentation.
- สายเคเบิลเชื่อมต่อData/connection cable.
- ขั้วต่อทองเหลืองBrass valve connector.
- Yellow Short HoseShort yellow hose; confirm its rating and inclusion for the selected package.
- บรรจุภัณฑ์ค้าปลีกProduct box.
คำถามที่พบบ่อย
Vacuum Gauge Setup Questions
How does LM100 support an AC system vacuum test?
LM100 is used for refrigeration, HVAC, and automotive A/C system vacuum monitoring and pressure-retention testing. It helps users observe vacuum-level changes and evaluate refrigeration-system sealing condition.
Does LM100 support refrigerant mode?
No. LM100 is a smart digital vacuum gauge and pressure-retention test tool, not a complete refrigerant manifold gauge. It has no refrigerant database or high/low manifold valves; compare LM120, LM150, or LM160 when those functions are required.
สามารถตรวจหาจุดรั่วได้หรือไม่?
A pressure change directs the next inspection. Check the setup, then use an approved method to locate the leak.
What units can LM100 switch between?
LM100 supports one-button switching between hPa, mbar, Torr, inHg, °C, °F, and K.
Can LM100 connect to LM130?
Yes. LM100 has an integrated microprocessor and communication interface that connects to LM130 for synchronized high-precision data transmission.
What pressure limit should I watch before testing?
- LM100 measuring range: -101 kPa to 6 MPa (approximately -1.01 to 60 bar).
- LM100 measuring range: -101 kPa to 6 MPa; absolute limit: 10 MPa / 100 bar. The absolute limit is not an operating target.
- Standard hose: 600 PSI / 4.13 MPa / 41.3 bar working pressure; 3000 PSI / 20.68 MPa / 206.8 bar limit.
Use the lowest working rating of the system, gauge, and hose.
Does LM100 automatically power off?
Yes. LM100 automatically powers off after 20 minutes of inactivity to save energy.
ฉันควรตรวจสอบอะไรบ้างก่อนสั่งซื้อ?
Confirm the required measurement range and units, hose/connector rating, included accessories and whether you also need charging valves, refrigerant data or temperature probes.
What is the LM100 vacuum range?
The vacuum range is 0–2000 mbar / 0–1500 Torr. Vacuum resolution is 0.1 hPa, 0.1 mbar, 0.1 Torr, or 0.01 inHg depending on the selected unit.
สิ่งที่รวมอยู่ในแพ็คเกจ?
The package includes the LM100 main unit, product box, user manual, data/connection cable, and brass valve connector. Confirm whether the selected package includes the yellow short hose or any additional accessories, and check the hose rating.