AUTOOL BT30 · Fused OBD Memory-Saver Power Cable

Supply Temporary Backup Power During Battery Replacement

Maintain temporary vehicle memory during an approved 12 V battery replacement with a suitable 10–14 V backup source. A fused OBD connection and live voltage/current display help technicians monitor the temporary supply while following the vehicle procedure.

  • 10–14 V Backup Source
  • Live Voltage / Current Display
  • Fused OBD Path
  • 0.5 m Clamp + 0.4 m OBD Leads
  • Temporary Memory Support
AUTOOL BT30 ECU emergency power supply cable main product image

Ключевые особенности

Monitor Temporary 10–14 V Backup Power

Temporary ECU Backup Power During Battery Replacement

During vehicle battery replacement, BT30 supplies backup power through the OBD interface to help keep the ECU and vehicle electronic systems powered.

Voltage And Current Display

The high-definition digital display makes it easier to observe voltage and current changes while the device is operating.

Observe Static and Possible Leakage Current

After connecting an external 12V battery and disconnecting the original vehicle battery negative terminal, the current display can help observe vehicle static current and possible leakage current.

Built-In 3A Fuse Protection

BT30 uses a 3 A fuse for the cable and output circuit. Match the fuse type and rating to the supplied cable and holder; confirm the operating-current requirement with AUTOOL перед заказом.

Многоуровневая электрическая защита

BT30 supports overcurrent protection, overvoltage protection, and reverse polarity protection to reduce risks caused by circuit faults or incorrect connection.

Insulated Clamp And Cable

The insulated cable, fully enclosed clamp design, pure copper clamp teeth, and thickened spring improve grip stability and safer handling.

10–14V Backup Supply

BT30 operates from a 10–14V source, with a 0.5m clamp-side cable and 0.4m OBD-side cable for the service connection.

ECU Power During Battery Replacement

Connected to a suitable spare battery and the vehicle OBD interface, BT30 supplies backup power during battery replacement to help keep vehicle electronics powered.

Граница обслуживания

Use only for approved temporary ECU/memory support during battery replacement. Do not use as a charger, jump starter, or programming supply.

Рабочая Температура

Рабочая температура: от -20 ° C до 60 ° C.

Гарантийное обслуживание в течение 3 лет

Основной блок: 3-летняя гарантия. Стандартные аксессуары: 1-летняя гарантия. Гарантийные условия.

Как использовать

Connect Backup Power Before Battery Removal

Шаг вперед1 / 5

Confirm The Procedure

Connect the red clamp to the positive terminal and the black clamp to the negative terminal. After correct connection, the screen displays voltage data.

Verify that the vehicle permits OBD backup power and identify settings or systems affected by battery replacement.

Безопасность и совместимость

Confirm the Source, Fuse and Vehicle Procedure

Vehicle Procedure First

Some vehicles restrict backup power through the diagnostic connector; follow the model-specific service information.

Not A Programming Supply

BT30 is not specified for voltage-stabilized ECU flashing or programming.

No Jump Starting Or Charging

Do not use the lead to crank the engine or charge a battery.

3 A Fused Path

Do not bypass the fuse or power loads beyond the backup-memory purpose. Replace a blown fuse only with the exact type and rating specified by the delivered manual and fuse holder; do not substitute 5 A based on generic advice.

Prevent Terminal Shorts

Keep disconnected main-battery leads isolated while backup power is present.

Monitor Backup Current

Use the current display to monitor the temporary backup connection during battery replacement.

Pre-Use Requirements

Review the battery, sleep mode, key distance, current display, fuse replacement, and storage requirements before using BT30.

Spare Battery Requirements

Use a fully charged 12V spare battery.

Do not use a low-voltage battery; if the device alarms immediately, replace it with a battery above 12V.

Battery Replacement Safety

During battery replacement, keep the vehicle power switch OFF and do not turn on electrical appliances.

Correct Fuse Replacement

If the fuse blows, replace it with a 3A or 5A fuse only.

Replace a blown fuse with the exact type and rating specified for the supplied BT30 cable and fuse holder.

Условия хранения в сухом виде

Store the product in a dry place and avoid hot, humid, or non-ventilated storage.

Характеристики

Voltage, Fuse and Current Fields

Предыдущая версия

Предыдущая версия — ECU backup power / No display

Новая версия

Новая версия — Voltage/current display / Leakage check / Circuit protection

Технические характеристики изделия
ПараметрЗначение
Планирование10–14 В постоянного тока
взрыватель3 A; confirm the rating marked on the supplied cable and fuse holder. For applications requiring the separate <7 A working-current specification, confirm the correct version with AUTOOL.
ДисплейНапряжение и ток
ЦельTemporary ECU/memory support during approved battery replacement

Руководство и поддержка

Confirm the Fuse, Source and Vehicle Procedure

AUTOOL BT30 User Manual preview
Руководство / PDF

AUTOOL Руководство пользователя BT30

Open the PDF manual for BT30 backup-source connection, OBD power delivery and voltage monitoring, with fuse protection, battery-service safety and troubleshooting support.

AUTOOL BT30 packing list and package contents

Комплектация

Check the Cable, Fuse and Included Parts

  • BT30 CableIntegrated OBD connector, display, battery clamps, and 3 A fuse.
  • Инструкция по эксплуатации и коробкаDocumentation and retail package.
  • Включенные компонентыThe package image shows the BT30 product box, user manual, and main OBD emergency power cable.
  • Основной блокAUTOOL BT30 OBD emergency power cable
  • Cable / ClampIntegrated power clamp and OBD interface

Часто задаваемые вопросы (FAQ)

Backup-Power and Battery-Replacement Questions

Why Does The Alarm Trigger And Blow The Fuse During Use?

Before use, make sure the vehicle is in sleep mode and keep the car key at least 3 meters away from the vehicle. This helps prevent the high-current alarm from being triggered. The fuse on BT30 will only blow when high current passes through the device.

Why Is There No Current Display?

After connecting an external 12V battery, disconnect the negative terminal of the original vehicle battery. This allows the load current to be displayed. Treat the displayed current as a screening observation under the stated setup, not a complete parasitic-draw diagnosis.

What Should I Do If The Fuse Blows?

If the fuse opens, stop and check the connection. The replacement must match the type and rating marked on the supplied fuse holder; never exceed 5 A. If the marking is unclear, confirm the correct fuse with AUTOOL перед заменой.

Why Does The Device Beep As Soon As It Is Connected To The Vehicle Battery?

The beeping alarm may occur because the battery voltage is too low. Replace the battery with one that has a voltage greater than 12V.

Why Doesn’t The New Device Power On After Connecting To The Battery?

Check whether the connected battery is a vehicle battery. If a jump starter or power bank charger is connected, the device will not power on. Replace it with a vehicle battery for proper power supply.

Can BT30 Power ECU Programming?

No. It is a temporary battery-replacement memory-support cable, not a regulated programming power supply.

Отзывы клиентов

Нет отзывовПоделитесь своим опытом использования этого продукта первыми.

Оставить отзыв

Ваш адрес электронной почты не будет опубликован. Обязательные поля отмечены *.

AUTOOL Аварийный источник питания ЭБУ BT30
AUTOOL Кабель резервного питания ЭБУ BT30

US$29.00

Выбрать Этот продукт имеет несколько вариантов. Опции можно выбрать на странице товара. Официальный запрос на коммерческое предложение
Получите дополнительную скидку