AUTOOLautoolstore.com
Source: https://autoolstore.com/nb/product/automotive-smoke-leak-detector-sdt60/

AUTOOL SDT60 Røyklekkasjedetektor for biler

(18 omtaler)

US$95.00

  • 3-Year Warranty Main unit 3 years · Accessories 1 year
  • 90-Day Returns Eligible returns within 90 days
  • Official Store Genuine products · Direct support

AUTOOL SDT60 · Compact Automotive Smoke Leak Detector with Pressure Gauge

Add Pressure Monitoring to Portable Smoke Tracing

Watch pressure changes in the connected low-pressure test path, then follow escaping smoke to inspect the visible leak route. SDT60 combines a built-in air pump with a compact 1.6 kg body for permitted EVAP, intake, exhaust, fuel-tank, line-fitting, and vehicle-sealing checks without an external air source.

  • Built-In Pump, No Shop Air
  • Pressure-Gauge Feedback
  • 1.6 kg Main Unit
  • Permitted Low-Pressure Systems
  • Cold And Overheat Protection
AUTOOL SDT60 smoke leak detector

Key Features

Built-In Pump with a Compact Pressure Display

Pressure Gauge Leak Check

The pressure gauge helps you assess leak severity by monitoring pressure changes during the test.

Rapid Smoke Generation

Press the smoke switch to generate smoke quickly. The connected test line can fill with smoke within about 30 seconds.

Built-In Air Pump

No external air source is required. The built-in air pump keeps setup simple for workshop, mobile, and DIY use.

EVAP / Intake / Exhaust / Fuel Tank Checks

For intake-system diagnostics, SDT60 works as an intake smoke tester. It also supports exhaust, EVAP, fuel-tank, line-fitting, and vehicle-sealing checks. Compatible vehicles include 12V cars, motorcycles, snowmobiles, ATVs, light trucks, and speedboats.

Lightweight and Portable

With a 1.6 kg main unit, SDT60 is easy to carry, store, and use in tight engine-bay spaces.

Overheat and Low-Temperature Protection

The detector automatically powers off around 75°C and supports operation down to -20°C.

Controls & Connections

Controls and connections are grouped for quick setup and easy identification during testing.

3 Years Warranty Support

Main unit: 3-year warranty. Standard accessories: 1-year warranty. Warranty Policy.

How to Use

Seal, Pressurize, Observe, Add Smoke, and Inspect

Step progress1 / 5
01

Add Testing Oil

Fill 10–15 mL baby oil or liquid paraffin into the detector. Do not overfill.

Safety & Compatibility

Use the Correct System Pressure and Vehicle Procedure

12V Power and Built-In Air Pump

Connect SDT60 to a 12V DC battery before use. The built-in air pump provides the test airflow, so you do not need an external air source.

Use the Pressure Gauge to Watch Test Pressure

SDT60 outputs less than 10 psi and less than 5 L/min. Watch the gauge for pressure changes in the connected test path, and stay within the pressure allowed by the vehicle or component service procedure.

Add 10–15 mL of Testing Oil

Use liquid paraffin or baby oil as testing oil. Add 10–15 mL before use and do not exceed this range.

Limit Continuous Use to 8 Minutes

Do not run SDT60 continuously for more than 8 minutes. Let the unit rest between tests.

75°C Overheat Protection

If the internal temperature exceeds 75°C, the unit automatically shuts off power. Let it cool before restarting.

Operating Temperature and Hot Surfaces

SDT60 supports operation down to -20°C. The round metal housing can become hot during use, so avoid touching hot surfaces directly.

Check Connections Before Starting Smoke

Before starting smoke, make sure the smoke hose and test line are connected securely and confirm the 12V power connection.

Trace the Leak with Smoke

Use visible smoke to trace the leak area. If no smoke appears, recheck isolation, flow, and the test setup before continuing.

Gauge Monitors Pressure Only

Use the pressure gauge to monitor the test, not to set or increase pressure.

Never Refill While Running

Do not refill testing oil while the unit is running.

Test Results

Use Pressure and Smoke as Separate Test Clues

Use Pressure Changes to Guide Inspection

Use the pressure gauge to track line-pressure changes and guide the next leak-inspection step.

Visible Smoke Escape

Check that the outlet is not an intentional opening, then inspect, repair and retest the exact area.

No Visible Smoke

Verify access, isolation, valve state and smoke delivery before moving to functional diagnosis or another test method.

Compare Models

Compare Portable Gauge and Pump Options

Model Guide

Choose one or more models. SDT60 is selected by default.

1 model selected

AUTOOL SDT60 is selected. Choose another model for a side-by-side comparison.

SDT60 comparison

Comparison of AUTOOL Smoke Leak Detectors
Product NameSDT60
Smoke Output & Protection
Working Principle
Low Oxygen Combustion
Test Oil Filling Volume
10-15ml
Rated Output Pressure
<10 psi machine-rated output; use the target-system procedure.
Rated Output Flow
<5L/min
High-Temperature Protection
Stops working above 75°C
Response Time
Produces smoke in 5 seconds
Power & Physical Size
Input Power
DC12V
Rated Power
50W
Net Weight (Main Unit)
1.6kg
Main Unit Dimensions
145mm*80mm*200mm
Monitoring & Controls
Flow Meter Window
×
Pressure Gauge
✓
Air Source Type
Built-in Air Pump
Mode Output
Smoke Mode
Dual Pressure Mode
×
Flow Adjustment Knob
×
Oil Drain Valve
×
Fault Indicator Light
×
Oil Level Gauge
×

Manual & Downloads

Use the Manual for Setup and Test Pressure

AUTOOL SDT60 user manual cover
Manual / PDF

AUTOOL SDT60 User Manual

Open the PDF manual for SDT60 built-in pump operation, pressure-gauge checks, permitted smoke tests, system connections, test-oil safety, and troubleshooting.

AUTOOL SDT60 package contents

Package

What’s Included

  • Main UnitAUTOOL SDT60 Smoke Leak Detector
  • Power Cable12V battery power cable / clamps
  • Smoke HoseSmoke output hose
  • AdaptersRed cone / line adapters
  • Oil ToolsFunnel and oil bottle
  • HookHanging hook for engine bay use
  • HåndbokUser manual
  • Testing OilCheck the package contents to see whether testing oil is included. If it is not included, use liquid paraffin or baby oil.

Vanlige spørsmål

Gauge, Pump, and Connection Questions

What Testing Oil Should I Use for SDT60?

Use liquid paraffin or baby oil as the testing oil for SDT60 smoke generation.

How Much Testing Oil Should I Add?

Add 10–15 mL before first use and do not exceed this range. When refilling, pour out the remaining oil first and add about 10 mL fresh testing oil.

Does SDT60 Need an External Air Pump?

No. SDT60 has a built-in air pump, so it does not require an external air source for normal use.

What Power Supply Does SDT60 Need?

SDT60 requires connection to a 12V DC battery for operation.

How Long Can SDT60 Run Continuously?

Do not run the detector continuously for more than 8 minutes. Let the unit rest between uses.

Why Does the Detector Shut Off Automatically?

If the temperature exceeds 75°C, automatic overheat protection turns off the power. Let the detector cool before using it again.

Can SDT60 Work in Cold Environments?

Yes. SDT60 can operate at temperatures down to -20°C.

How Does the Pressure Gauge Help?

The pressure gauge helps you assess leaks by showing pressure changes during the test. The reading can help distinguish no obvious leak from a small or more severe leak.

Which Systems Can SDT60 Test?

For engine-related leak checks, SDT60 works as an engine smoke tester across intake, crankcase, oil-seal, throttle, and intake-manifold systems. It also supports low-pressure checks on exhaust, vehicle-sealing, fuel-tank, intercooler-air, coolant-tank, and line fittings.

How Does SDT60 Differ from SDT101 and SDT103?

SDT60 has a built-in air pump and can be used directly with a 12V battery. SDT101 and SDT103 require an external air source.

Customer Reviews

  1. A

    Ahmed ✓ Verified Purchase –

    A reliable tool

    I’ve been using the AUTOOL SDT60 for a few months now. It’s incredibly portable, allowing me to move from my garage to a client’s car. The built-in air pump means I don’t need any extra equipment, and setup takes seconds.
    I also appreciate its safety features—the automatic shutoff at 75°C and the clear, sensitive pressure gauge make it easy to quickly locate leaks. It runs directly from a 12V car battery, so it’s always ready to go, no matter where I’m working.

    0 of 0 found this review helpful
  2. FL

    Fuan L. ✓ Verified Purchase –

    A cost-effective smoke leak detector that can visually detect leaks in your car.…

    A cost-effective smoke leak detector that can visually detect leaks in your car. It can be tested using baby oil, significantly improving the efficiency and accuracy of leak diagnosis.

    0 of 0 found this review helpful
  3. R

    Robertmchaffie ✓ Verified Purchase –

    much easier to find vacuum leaks

    The SDT60 eliminates the need for a separate air source; it comes with its own air pump and a pressure gauge, allowing you to monitor pressure changes at any time. If you are trying to track down a leak, you can’t beat a good smoke machine. This thing is the G.O.A.T., and will save you a load of time.

    0 of 0 found this review helpful
Leave A Review

Din e-postadresse vil ikke bli publisert. Obligatoriske felt er merket med *

Choose your language

Choose your language

Prefer another language?

Fortsette
Language
AUTOOL SDT60 Røyklekkasjedetektor for biler
AUTOOL SDT60 Røyklekkasjedetektor for biler

US$95.00

Velg alternativ Dette produktet har flere varianter. Alternativene kan velges på produktsiden
Get Extra Discount