AUTOOL OD750 공압 오일 배출기 및 추출기
US$1,899.00
- Extraction, Collection + Tank Discharge
- 100리터 저장 탱크
- 12 L Transparent Prechamber
- 20 L Catch Pan
- Extraction, Collection + Tank Discharge: Handle probe extraction, gravity collection, and pneumatic tank discharge with one station.
- 100리터 저장탱크: Store recovered waste oil in the 100 L main tank for high-volume workshop service.
- 12 L Transparent Prechamber: Measure and inspect extracted oil in the graduated 12 L transparent prechamber.
- 20 L Catch Pan: Collect gravity-drained oil with the height-adjustable 20 L catch pan.
- Probe Access + Mobility: Use the included long and short probes for extraction, then reposition the station on its casters and push handle.
- 3 - 년 보증 본체 3년, 부속품 1년
- 90- 일 반품 90일 이내 반품 가능
- 공식 스토어 정품 · 직접 지원
AUTOOL OD750 · 100 L Pneumatic Oil Drainer and Extractor
Measure Extraction Before Tank Transfer
Recover used oil by probe extraction or a height-adjustable catch pan, then collect it in a mobile workshop tank. A transparent pre-chamber lets technicians inspect and measure extracted oil before transfer, while long and short probes support compatible service routes. Compressed air powers vacuum generation and controlled tank discharge as separate procedures.
- 진공 + 중력 회수
- 100 L Main Tank
- 12 L Transparent Pre-Chamber
- 20 L Catch Pan
- Long + Short Probes

주요 특징
See Extracted Oil in the 12 L Chamber
Vacuum, Gravity + Tank Discharge Paths
Use probe extraction, gravity collection through the catch pan, or controlled discharge from the storage tank.
100 L Main Tank
The high-capacity storage tank reduces transfer frequency in suitable workshop use.
12 L Transparent Pre-Chamber
Observe and measure extracted oil before transferring it to the main tank.
20 L Catch Pan
The height-adjustable pan collects gravity-drained oil beneath a raised vehicle.
긴 프로브와 짧은 프로브
Multiple probe lengths support compatible dipstick-tube and service-port extraction routes.
Mobile Bay Design
Wheels, swivel casters, handle and probe storage keep the station movable and organized.
3년 보증 지원
본체: 3년 보증. 표준 부속품: 1년 보증. 보증 정책.
이용 방법
폐유를 수집, 추출 및 배출합니다.
공기 공급 장치를 준비하세요
Connect the specified clean compressed-air supply and inspect the regulator, hoses, valves and tank level.
Choose the Recovery Route
Use a compatible extraction probe for suction service or position the catch pan for gravity draining.
Build and Isolate Vacuum
Create vacuum as directed, isolate the air supply, then connect the selected probe and monitor fluid entering the pre-chamber.
Transfer to the Main Tank
Close the extraction path and transfer collected oil from the pre-chamber or pan into the storage tank.
Discharge the Storage Tank
Use the separate low-pressure discharge procedure, keep the outlet secured in an approved waste container and release tank pressure after transfer.
안전성 및 호환성
오일 경로, 프로브 및 공기 공급 장치를 일치시키십시오.
Use the Model Air Settings
Compressed-air input, extraction vacuum and tank discharge are separate operating conditions; use the specified setting for each.
오일 온도 조절
Keep waste oil within 40–80 °C and protect against hot fluid and surfaces.
Use Approved Waste Oil Only
Do not use the unit with gasoline, diesel, brake fluid, methanol- or ketone-containing liquids, or other flammable fluids.
Confirm the Probe Route
Verify that the selected probe can enter the vehicle service route without forcing, kinking or detaching.
Release Pressure After Use
Vent the tank through the instructed procedure before service, storage or opening a connection.
기술 사양
Tank, Pan and Oil Temperature Specifications
| 스펙 | 가치관 |
|---|---|
| 메인 탱크 | 100 L |
| 예비실 | 12 L |
| Catch Pan | 20 L |
| 오일 온도 | 40-80 ° C |
사용 설명서 및 지원
운항 및 공기 공급 지침을 찾아보세요
AUTOOL OD750 사용자 설명서
Open the PDF manual for OD750 probe extraction, gravity collection, pre-chamber measurement and main-tank discharge, with operating safety and troubleshooting support.

패키지 내용물
탱크, 프로브 및 포함된 부품을 확인하십시오.
- 본체AUTOOL OD750 pneumatic oil extractor and drainer
- 오일 캐치 팬20 L height-adjustable gravity-drain pan
- Extraction ProbesLong and short probes for compatible service routes
- 서비스 호스Extraction and controlled-discharge hose set supplied for the machine
- 사용 설명서AUTOOL OD750 operation manual
자주 묻는 질문
석유 회수 및 공기 공급 관련 질문
What service is OD750 designed for?
Use probe extraction, gravity collection through the catch pan, or controlled discharge from the storage tank.
How should I confirm the extraction route?
Verify that the selected probe can enter the vehicle service route without forcing, kinking or detaching.
What oil temperature should I use?
Keep waste oil within 40–80 °C and protect against hot fluid and surfaces.
Which air setting should I use?
Compressed-air input, extraction vacuum and tank discharge are separate operating conditions; use the specified setting for each.
Which liquids must not be used?
Do not use the unit with gasoline, diesel, brake fluid, methanol- or ketone-containing liquids, or other flammable fluids.





































리뷰가 아직 없습니다.이 제품 사용 경험을 가장 먼저 공유해 보세요.