AUTOOL LM120+ Digital Refrigerant Manifold Gauge
US$149.00
- Dual-Side Pressure Control
- Probe-Ready SH/SC
- 진공, 고정 및 충전 모드
- 백라이트 멀티 유닛 디스플레이
- Dual-Side Pressure Control: Read high- and low-side gauge pressure together, using dedicated valves, a sight window, and standard 1/4-inch connections.
- Probe-Ready SH/SC: Display T1/T2 and calculate SH/SC when compatible wired clamps are connected and the correct refrigerant is selected; clamps are sold separately.
- 진공, 고정 및 충전 모드: Supports relative-vacuum monitoring, timed pressure-retention checks, and refrigerant-charging assistance.
- 백라이트 멀티 유닛 디스플레이: Switch among five pressure units and Celsius or Fahrenheit on the large backlit LCD.
- 3 - 년 보증 본체 3년, 부속품 1년
- 90- 일 반품 90일 이내 반품 가능
- 공식 스토어 정품 · 직접 지원
AUTOOL LM120+ · Dual-Temperature Digital Refrigerant Manifold Gauge
Read Both Sides with Probe-Ready SH/SC
Measure high- and low-side pressure across 0–6 MPa and control refrigerant flow with dedicated valves, a sight window and 1/4-inch fittings. Add compatible wired temperature clamps, sold separately, for T1/T2 readings and superheat/subcooling calculations with the correct refrigerant selected. Relative-vacuum monitoring, timed pressure retention and filling assistance support refrigeration installation and service.
- 0–6 MPa 게이지 압력
- T1/T2 with Optional Clamps
- 과열/과냉각
- 시간적 압력 유지
- Sight Window & 1/4-Inch Fittings

주요 특징
Two Temperature Channels Beside High- and Low-Side Pressure
Simultaneous High/Low Pressure
Read high- and low-side pressure during compatible A/C and refrigeration service work.
Dual Temperature Inputs
Displays real-time T1 and T2 temperature readings when compatible clamp-on temperature probes are connected and properly attached to pipes. Display T1/T2 with compatible wired clamps; full contact with the pipe is required.
Superheat And Subcooling
Calculate SH/SC after selecting the correct refrigerant and connecting stable temperature probes.
Relative-Vacuum Mode
Supports relative vacuum measurement, pressure leak measurement, and leak time recording for service checks within the rated range. Monitor pressure during an approved evacuation procedure.
Timed Pressure-Retention Mode
Show initial/current pressure, ΔP and elapsed time for system-tightness assessment.
충전 지원
Use the valves, sight window, selected refrigerant data and correctly rated hoses within the equipment-specific procedure.
Built-In Refrigerant Data
The built-in refrigerant database helps reference pressure and evaporation temperature data and supports superheat and subcooling calculations when probes are connected. Shared manual lists 89 refrigerants, but the exact product/version database should be confirmed when a specific gas is critical.
백라이트 멀티 유닛 디스플레이
The large LCD with backlight improves visibility and makes data easier to read during workshop or field maintenance. Switch among kPa, MPa, bar, inHg and PSI and between Celsius and Fahrenheit.
Durable Handheld Construction
High-strength engineering plastic and flexible non-slip silicone help make the gauge solid, comfortable, and easy to hold. Non-slip engineering-plastic body, long-life valves and standard fittings support workshop use.
기기 무게
The LM120+ instrument weighs 950 g.
3년 보증 지원
본체: 3년 보증. 표준 부속품: 1년 보증. 보증 정책.
이용 방법
Connect Both Sides, Clamp Both Lines, and Stabilize
Identify The Refrigerant
Select the refrigerant confirmed by the vehicle or equipment information before interpreting the LM120+ readings.
Confirm Kit And Ratings
Check probe inclusion, battery preparation and the separate gauge, hose and system ratings.
Inspect, Zero And Connect
Close valves, inspect fittings/hoses, choose refrigerant and units, zero if needed, then connect according to flow direction.
Measure Or Service
Use pressure/refrigerant, vacuum or retention mode. Connect both temperature clamps firmly when T1/T2 or SH/SC is needed.
Close And Review
Follow the manual’s valve and disconnect sequence, allow pressure to reach a safe point and interpret results with the system specification.
안전성 및 호환성
Confirm Refrigerant, Ports, Hoses, and Limits
Use The Lowest Working Rating
Operate within the lowest working rating of the system, gauge and hose. The standard hose is listed at 600 PSI working pressure.
Inspect Before Pressure Work
Replace damaged hoses, seals and fittings before connection.
Do Not Guess Refrigerant
Select only a refrigerant already identified by reliable system information.
Wear PPE And Ventilate
Use suitable protection and ventilation and keep the instrument out of hot, humid, flammable, explosive or strong-EMF environments.
액세서리 확인
Temperature-dependent results require compatible probes; do not promise them when the selected package omits the clips.
회로 수정 없음
Do not modify the internal circuit, to avoid instrument damage or safety hazards.
Wear Qualified Protection
Wear qualified protective equipment during testing.
적절한 환기를 보장하세요
Use the instrument in a well-ventilated environment to reduce the risk of inhaling toxic gases.
시험 결과
Interpret Pressure and Dual Temperature Together
Pressure Pair
Compare high- and low-side pressure with the known refrigerant, temperature and equipment procedure to select the next check.
SH And SC
Use only after refrigerant selection and stable pipe-probe contact; bad contact can invalidate the calculation.
Retention ΔP
If retention pressure changes, verify the connections and continue with an approved leak-location method.
진공 트렌드
Judge against the specific service target and stability period, not a generic elapsed time.
모델 비교
Compare Manifold Display and Sensor Options
모델 가이드
Choose one or more models. LM120+ is selected by default.
| 작업에 맞는 것을 선택하세요 | LM120 | LM120+ | LM150 | LM160 |
|---|---|---|---|---|
| Selection Criteria | ||||
| 구성 초점 | Core digital manifold | Plus kit with three-color hose/probe capability | Higher refrigerant-count manifold with two clamps shown | Program-controlled, 8-language manifold |
| Probe inclusion | Confirm package | 지원 가능; 이 구성에는 클램프가 포함되어 있지 않습니다. | 패키지에 두 개가 들어있습니다. | 패키지에 두 개가 들어있습니다. |
사용 설명서 및 다운로드
설치 및 서비스는 설명서를 참조하십시오.

AUTOOL LM120+ User Manual
Open the PDF manual for LM120+ dual-pressure readings, temperature probes, superheat and subcooling calculations, charging modes, safe connections, and troubleshooting.

묶음
포함 된 것
- LM120+ Main UnitDigital AC manifold gauge for refrigerant service.
- Three-Color Hose SetRed, blue and yellow hoses for the plus configuration; confirm ratings and inclusion.
- 어댑터/커플러Connection hardware; exact items depend on the selected package.
- 보관 케이스보호 케이스.
- 설명서 및 소매용 박스Shared model documentation and packaging.
- Temperature ClampsCompatible wired test clips are required for temperature and SH/SC functions and are not included in this configuration; confirm before ordering.
자주 묻는 질문
Dual-Temperature Manifold Questions
Is LM120+ a separate product from LM120?
Yes. Treat it as its own sellable configuration and verify its package rather than merging it into LM120.
Are The Temperature Clamps Included?
No. Compatible temperature clamps are required and sold separately. LM120+ supports dual temperature measurement when the clamp probes are connected to the instrument and fully seated against the refrigeration pipes. Confirm the selected kit before purchase.
Can LM120+ Calculate Superheat And Subcooling?
Yes. The gauge calculates SH superheat and SC subcooling when the correct refrigerant is selected and compatible temperature clamps are connected firmly with full contact on the refrigeration pipes.
How many refrigerants are stored?
The shared manual lists 89, while other page comparison material may differ. Confirm the exact database/version if a specific refrigerant is essential.
Does it identify refrigerant?
No. It uses a selected refrigerant database; identification remains a separate task.
Can it locate leaks?
No. Timed pressure retention shows pressure change over the selected period; use an approved method to locate the leak.
What must I confirm about pressure?
Check the system, gauge and hose working ratings separately and use the lowest applicable value.
무엇인가 AUTOOL LM120+ Used For?
LM120+ is an auxiliary digital refrigerant manifold gauge for installation, testing, and maintenance of refrigeration equipment such as air conditioners and cold storage systems. It supports dual pressure testing, vacuum measurement, pressure leak testing, refrigerant filling assistance, multi-unit switching, and refrigerant data reference.
- Four 1.5 V AA/LR6 batteries; confirm whether batteries ship with your package.
When is LM120+ preferable to LM160?
Choose based on required workflow and package. LM160 adds program control and multilingual operation; LM120+ remains a direct handheld manifold configuration.
What Pressure Range Does LM120+ Support?
The instrument measures gauge pressure. The combined warning range is -101kPa to 6MPa, or -0.1bar to 60bar. The pressure test range is 0kPa-6000kPa, the vacuum test range is -101kPa-0kPa, and the instrument overload limit is 10MPa, or 100bar.
What Is The Standard Hose Pressure Limit?
The standard hose maximum operating pressure is 600PSI, approximately 4.13MPa or 41.3bar. The hose limit pressure is 3000PSI, approximately 20.68MPa or 206.8bar. Confirm the tested equipment pressure first, and use suitable replacement hoses if the packed hoses do not match the pressure requirement.
What Batteries Does LM120+ Use?
LM120+ uses 4 × 1.5V AA / LR6 batteries. Prepare batteries separately if your order or shipping region does not include them.
How Many Refrigerants Are Built Into LM120+?
The LM120 / LM120+ manual lists a built-in 89-kind refrigerant NIST database. The comparison chart on the product page may show a different refrigerant species count by model or product version, so confirm the database version with support if this detail is critical for your work.
LM120과 LM120+의 차이점은 무엇인가요?
According to the comparison chart, both LM120 and LM120+ support vacuuming mode, refrigerant mode, pressure leak test, foldable hook, visible refrigerant window, and high/low pressure valves. LM120+ additionally shows trichromatic tube support and two wired temperature clamp support.
How Should I Choose Between LM120+, LM150, And LM160?
Choose LM120+ if you need a balanced digital manifold gauge with trichromatic tube, wired temperature clamp support, visible refrigerant window, and high/low valves. Choose LM150 when you need its 93-refrigerant database and two included wired temperature clamps; compare the required probes and functions before ordering. Consider LM160 if you need the higher-end model with program control system, two-side handrails, more language options, and broader database support.
압력 누출 테스트 전에 무엇을 확인해야 할까요?
Check pipe fittings and hoses before testing. If any damage is found, replace the damaged part immediately to avoid improper use or accidents. Also confirm that the equipment pressure is within the instrument range and that the hose rating is suitable.
Where Can I Download The LM120+ Manual?
Use the Download section on this page to open the AUTOOL LM120 / LM120+ manual PDF. The manual includes cautions, specifications, product structure, refrigerant filling, vacuum operation, pressure leak testing, common problems, maintenance, warranty, and return/exchange information.
보증 기간은 얼마나 되나요?
본체: 3년 보증. 표준 부속품: 1년 보증. 보증 정책.

























Zero Haggai ✓ 구매 확인 완료 -
It's decent .
It’s decent . You can recalibrate and zero out the pressure but you could have pressure in your lines still. Temperature sensors are good but would work better if the clamps had a copper insert for the sensor that covered the surface area of the hoses toy clamp to. I’m gonna make some new clamps with my 3d printer and add space for thermal conducting material in the clamp so the sensor gets a more accurate reading. But still it’s decent for the cost.
Vivian Archibald ✓ 구매 확인 완료 -
좋은
These gauges work great they are pretty accurate and will recommend to others great value thank you
Renata Wyat(t) ✓ 구매 확인 완료 -
아주
Give your freedom of thermostats and tapes around the pipes to check for super heat and sub cooling, it’s just great.recommend 100%