AUTOOL SDT203 Automotive Smoke Leak Detector
US$159.00
- Pressure + Flow Monitoring
- Pompa dell'aria integrata
- EVAP + System Leak Tracing
- 23 Intake Adapters
- Pressure + Flow Monitoring: View line pressure and airflow changes while adjusting output for the selected low-pressure test.
- Built-In Air Pump: Run smoke checks without an additional air pump or shop-air connection.
- EVAP + System Leak Tracing: Trace escaping smoke in permitted EVAP, fuel-tank, intake, exhaust, sealing, and line-fitting checks.
- 23 Intake Adapters: Use 23 included intake adapters to connect and seal varied test openings.
- Compact Hook Design: Position the compact unit near the test area with the integrated hook.
Caricamento del modulo di richiesta in corso...
- 3 anni di garanzia Unità principale 3 anni · Accessori 1 anno
- Resi entro 90 giorni Resi idonei entro 90 giorni
- Negozio ufficiale Prodotti originali · Assistenza diretta
AUTOOL SDT203 · Smoke Tester with Pressure and Flow Monitoring
Combine Pressure, Flow, and Smoke Clues
This automotive smoke machine lets you view line pressure and airflow changes while adjusting output for the selected low-pressure test, then follow escaping smoke to the leak path. Its built-in pump removes the need for shop air, 23 intake adapters help seal varied openings, and the compact hook positions the unit near permitted EVAP and vehicle-system checks.
- Built-In Pump, No Shop Air
- Pressure And Flow Feedback
- Adjustable Flow Output
- 23 Intake Adapters
- Hook-Mounted Test Position

Funzionalità principali
Built-In Pump, Pressure Gauge, and Flow Meter
External Pressure Gauge
The pressure gauge helps you see whether the test line is holding pressure. Stable or rising pressure usually indicates better sealing, while falling pressure may indicate a leak.
Flow Meter Window
The flow meter shows airflow changes during testing, while the adjustment knob lets you control output for the test.
Flow Adjustment Knob
Different vehicle lines may require different airflow settings. The adjustment knob helps control flow to protect the test system.
Smoke Starts in About 5 Seconds
Smoke generation starts in about 5 seconds, helping users locate leaks sooner.
Pompa dell'aria integrata
No additional air pump is required. The built-in pump saves setup time and helps reduce extra tool cost.
EVAP and Fuel Tank Systems
Can be used for EVAP and fuel tank leak checks with adapters that match the vehicle test port or connection.
Intake and Exhaust Checks
Helps check intake and exhaust systems, engine sealing areas, and line fittings by showing where smoke escapes.
Line & Fitting Adapter Support
The smoke hose, adapters, rubber kits, and airbag adapter help connect the unit to different line openings and fittings.
Vehicle Sealing Tests
Useful for locating suspected sealing leaks where smoke can reveal gaps, cracks, or loose fittings.
Compact Hook Design
The compact body and hook make it easy to carry, store, and position near the test area.
Overheat and Low-Temperature Protection
Automatic temperature protection shuts down the unit if it exceeds the operating-temperature limit, while low-temperature protection supports operation in cold environments.
Twenty-Three Intake Adapters
The SDT203 package includes 23 intake adapters; confirm the exact connection and seal for the system under test.
3 anni di garanzia e assistenza
Unità principale: 3 anni di garanzia. Accessori standard: 1 anno di garanzia. Politica di garanzia.
Istruzioni per l’uso:
Seal, Pressurize, Watch Flow, Add Smoke, and Inspect
Add Testing Oil
Fill 10–15 mL baby oil or liquid paraffin into the oil refill port before use. If too much oil is added, drain some oil out before operation.
Install the Hook and Open Airflow
Install the hook onto the hook port and position the detector securely near the test area if needed. Gently open the smoke flow control valve.
Connect the Smoke Hose
Turn off the vehicle ignition, disconnect the test line or access point, and connect the smoke hose between the smoke outlet and the line under test.
Connect 12V DC Power
Connect the red clamp to positive (+) and the black clamp to negative (-). A fully charged 12V vehicle battery is recommended for consistent performance.
Generate Smoke and Locate Leaks
Press the Smoke Mode switch. The unit generates smoke quickly. Depending on system volume, allow about 30 seconds or longer for the test line to fill, then inspect for escaping smoke; use a light if needed.
After stopping Smoke Mode, allow the unit to blow residual smoke out of the nozzle.
Confirm and Retest
Confirm any visible escape path against the system layout, repair the verified leak, and repeat the same controlled test. Continue with the vehicle procedure if no smoke is visible or the fault is intermittent or functional.
Sicurezza e compatibilità
Match Pressure, Medium, and Procedure to the System
12V Power and Built-In Air Pump
Connect SDT203 to a 12V DC vehicle battery before use. The built-in air pump provides the test airflow, so you do not need an external compressor.
Use Pressure and Flow Readings as Guides
SDT203 outputs less than 15 psi and less than 6 L/min. Use the pressure gauge and flow meter to watch the connected test path, and stay within the pressure allowed by the vehicle or component service procedure.
Adjust Airflow Gradually
Start with minimum airflow and increase only as needed for the connected line; SDT203 remains a low-pressure smoke tester.
Testing Oil Is Not Included
Testing oil is not included. Use liquid paraffin or baby oil and add 10–15 mL before use.
Limit Continuous Use to 8 Minutes
Do not run SDT203 continuously for more than 8 minutes. Automatic overheat protection shuts off power above 75°C. Let the unit cool before restarting.
A/C Inspection Scope
SDT203 is a low-pressure smoke detector. Use it on an isolated A/C line section only when the service procedure permits indirect smoke inspection.
A/C Inspection Workflow
For an approved A/C inspection, isolate and pressurize the line section according to the service procedure, then use smoke only as an indirect visual aid.
Use Smoke to Locate the Leak
Use visible smoke to locate the leak area, then repair and retest. If no smoke appears, recheck isolation, flow, and the test setup before continuing.
Respect Smoke-Test Exclusions
Keep smoke away from headlights and from any component or system where smoke testing is not permitted.
Switch Off Vehicle and Engine
Turn off the vehicle ignition and keep the engine off during vehicle leak tests.
Keep Liquids Away
Keep the unit out of water and other liquids, and do not use sticky liquids as testing oil.
Never Refill While Running
Do not refill testing oil while SDT203 is running.
Avoid Hot Metal Housing
Avoid touching the metal housing when it is hot.
Risultati del test
Read Pressure, Flow, and Smoke as Different Signals
Flow or Pressure Changes
Use pressure and flow behavior under the configured, sealed test setup to guide the next leak inspection step.
Visible Smoke Escape
Check that the outlet is not an intentional opening, then inspect, repair and retest the exact area.
No Visible Smoke
Verify access, isolation, valve state and smoke delivery before moving to functional diagnosis or another test method.
Confronta modelli
Compare Monitoring and Control Features
Guida al modello
Choose one or more models. SDT203 is selected by default.
| Ürün Adı | SDT50 | SDT60 | SDT100 | SDT101 | SDT102 | SDT103 | SDT106 | SDT203 | SDT205 | SDT205S | SDT206 | SDT208 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Smoke Output & Protection | ||||||||||||
| Principio di funzionamento | Low Oxygen Combustion | Low Oxygen Combustion | Low Oxygen Combustion | Low Oxygen Combustion | Low Oxygen Combustion | Low Oxygen Combustion | Low Oxygen Combustion | Low Oxygen Combustion | Low Oxygen Combustion | Low Oxygen Combustion | Low Oxygen Combustion | Low Oxygen Combustion |
| Test Oil Filling Volume | 10-15ml | 10-15ml | 10-15ml | 10-15ml | 10-15ml | 10-15ml | 10-15ml | 10-15ml | 10-15ml | 10-15ml | 10-15ml | 10-15ml |
| Rated Output Pressure | <10psi | <10psi | <10psi | 3.2Kpa(0.46psi) | <10psi | 3.2Kpa(0.46psi) | <12psi | <15 psi machine-rated output; use the target-system procedure. | <15psi | <15psi | <18psi | <10psi/35psi |
| Rated Output Flow | <5L/min | <5L/min | <5L/min | > 10L / min | >6 l/min | > 10L / min | <5L/min | <6L/min | <6L/min | <6L/min | <6L/min | <15L/min |
| Protezione dalle alte temperature | Stops working above 75°C | Stops working above 75°C | Stops working above 75°C | Stops working above 75°C | Stops working above 75°C | Stops working above 75°C | Stops working above 75°C | Stops working above 75°C | Stops working above 75°C | Stops working above 75°C | Stops working above 75°C | Stops working above 75°C |
| Tempo di risposta | Produces smoke in 5 seconds | Produces smoke in 5 seconds | Produces smoke in 5 seconds | Produces smoke in 5 seconds | Produces smoke in 5 seconds | Produces smoke in 5 seconds | Produces smoke in 5 seconds | Produces smoke in 5 seconds | Produces smoke in 5 seconds | Produces smoke in 5 seconds | Produces smoke in 5 seconds | Produces smoke in 5 seconds |
| Power & Physical Size | ||||||||||||
| Alimentazione in ingresso | DC12V | DC12V | DC12V | DC12V / 5A | DC12V | DC12V / 5A | DC12V | DC12V | DC12V | DC12V | DC12V | DC12V / 24V |
| Potenza nominale | 50W | 50W | 50W | 48W | 48W | 48W | 50W | 65W | 65W | 65W | 70W | 80W |
| Net Weight (Main Unit) | 1.5 kg | 1.6 kg | 1.6 kg | 1.6 kg | 1.6 kg | 1.15 kg | 3.5 kg | 1.7 kg | 3.2 kg | 3.2 kg | 3.5 kg | 4.2 kg |
| Dimensioni dell'unità principale | 145mm * * 80mm 200mm | 145mm * * 80mm 200mm | 180mm * * 102mm 143mm | 180mm * * 100mm 135mm | 180mm * * 102mm 143mm | 180mm * * 100mm 135mm | 110mm * * 135mm 210mm | 145mm * * 80mm 200mm | 295mm * * 295mm 207mm | 295mm * * 295mm 207mm | 150mm * * 150mm 275mm | 350mm * * 250mm 300mm |
| Monitoraggio e controlli | ||||||||||||
| Flow Meter Window | × | × | × | × | × | ✓ | × | ✓ | × | ✓ | ✓ | ✓ |
| Manometro | × | ✓ | × | × | ✓ | × | × | ✓ | ✓ | ✓ | ✓ | ✓ |
| Air Source Type | Built-in Air Pump | Built-in Air Pump | Built-in Air Pump | Fonte d'aria esterna | Built-in Air Pump | Fonte d'aria esterna | Built-in Air Pump | Built-in Air Pump | Built-in Air Pump | Built-in Air Pump | Built-in 2 Air Pump | Built-in Air Pump |
| Mode Output | Smoke Mode | Smoke Mode | Smoke Mode | Smoke Mode | Smoke Mode | Smoke Mode | Smoke Mode | Smoke Mode | Modalità aerea Smoke Mode | Modalità aerea Smoke Mode | Modalità aerea Smoke Mode | Modalità aerea Smoke Mode |
| Dual Pressure Mode | × | × | × | × | × | × | × | × | × | × | × | Standard 35 psi / EVAP 10 psi machine modes; use the vehicle procedure. |
| Flow Adjustment Knob | × | × | × | × | × | ✓ | × | ✓ | × | ✓ | ✓ | ✓ |
| Valvola di scarico dell'olio | × | × | × | × | × | × | × | × | ✓ | ✓ | ✓ | ✓ |
| Indicatore luminoso di guasto | × | × | ✓ | × | ✓ | × | × | ✓ | ✓ | ✓ | ✓ | ✓ |
| Indicatore di livello dell'olio | × | × | × | × | × | × | × | × | × | × | ✓ | ✓ |
Manuale e download
Use the Manual for Setup and Test Pressure

AUTOOL SDT203 User Manual
Open the PDF manual for SDT203 pressure and flow monitoring, smoke-output adjustment, adapter sealing, test-oil handling, operating safety, and troubleshooting.

CONFEZIONE
Cosa è incluso
- Unità principaleAUTOOL SDT203 smoke leak detector
- Scatola al minutoSDT203 retail box
- Cavo di alimentazione12V battery clamp cable
- Tubo per fumoSmoke output hose for connecting to the line under test
- Adattatori RFCone adapter, airbag adapter, straight adapter, hook, funnel, and accessories
- DocumentazioneManuale utente
DOMANDE FREQUENTI
Pressure, Flow, and Smoke Questions
What Testing Oil Should I Use for SDT203?
Use liquid paraffin or baby oil as the testing oil. Use dedicated smoke-testing oil if available; otherwise use the approved alternative specified for this model. Do not use water or sticky liquid.
How Much Testing Oil Should I Add?
Add 10–15 mL testing oil before use and do not overfill. Refill only when the smoke becomes thin, and do not add more than 15 mL at one time. Before adding fresh oil, drain remaining old oil from the detector. If too much oil is added accidentally, drain some oil out before operation.
Can SDT203 Detect EVAP Leaks?
Sì. Le serrature scorrevoli portatili e i catenacci a superficie possono essere usati per mettere in sicurezza una porta a scomparsa dall'esterno. Alcuni kit con catena di sicurezza consentono anche il bloccaggio esterno con chiave o manopola girevole. AUTOOL smoke leak detectors can test leaks in EVAP systems. Use the EVAP adapter or service tool that matches the vehicle test port.
Can SDT203 Directly Test Automotive A/C System Leaks?
No. Automotive A/C systems are high-pressure systems, while SDT203 is a low-pressure smoke leak detector with <15 psi rated output pressure. It cannot directly pressure-test the automotive A/C system for leaks. Use smoke only to help inspect an A/C line section after isolating and pressurizing it according to the service procedure.
How Can Smoke Help Locate a Leak in an Isolated A/C Line Section?
First isolate and pressurize the A/C line segment according to the vehicle or A/C service procedure. Then apply smoke along the line and observe whether escaping airflow disturbs the smoke. If escaping air moves the smoke, inspect that area for a possible leak.
What Systems Can SDT203 Test?
For automotive diagnostics, SDT203 supports low-pressure checks for EVAP, intake, exhaust, and fuel tanks. It can also check vehicle-sealing areas, engine sealing areas, and line fittings when the test point can be sealed safely.
What Power Supply Does SDT203 Need?
SDT203 uses 12V DC vehicle battery power. Connect the red clamp to positive (+) and the black clamp to negative (-). A fully charged 12V vehicle battery is recommended for consistent performance.
Can I Adjust the Pressure on SDT203?
SDT203 uses fixed output below 15 psi. Its flow adjustment knob controls airflow, not pressure mode. If separate Standard and EVAP pressure modes are required, compare SDT208.
What Accessories Are Included?
Check the product listing or your selected package option for the exact items included. The package includes the main unit, retail box, 12V battery clamp cable, smoke hose, cone adapter, airbag adapter, hook, funnel, adapter, and user manual. Testing oil is not included.
Il Nostro AUTOOL Smoke Leak Detector Models Differ?
- SDT203: built-in pump, pressure gauge, flow window, and flow adjustment.
- External-air EVAP: SDT103.
- Other built-in options: SDT106 Smoke Mode; SDT205/205S Air + Smoke; SDT206 dual pumps; SDT208 35 psi Standard / 10 psi EVAP.
Also compare output flow, gauges, oil controls, and accessories.
How Long Is the Warranty for SDT203?
Unità principale: 3 anni di garanzia. Accessori standard: 1 anno di garanzia. Politica di garanzia.





























Yasser ✓ Acquisto verificato -
Lillian, do you know who he is?
Lillian, do you know who he is?
The best sales representative I’ve ever dealt with.
One of the best companies I’ve ever bought from.
High-quality, unique tools—and this isn’t the first time I’ve bought from them.
Fast response and communication.
Shipping and packaging are the best I’ve ever seen—top-notch.
This wasn’t the first time I’ve bought from them, and it won’t be the last.
I’m writing this review with complete confidence.
Bishop Warren ✓ Acquisto verificato -
Arrived quickly, well packaged, and feels sturdy.
Arrived quickly, well packaged, and feels sturdy. Works well. Immediately identified a leak from the throttle body. Very useful tool. Doesn’t come with oil though – you need to order that separately.
David ✓ Acquisto verificato -
I’ve struggled with EVAP leaks for months until I got this AUTOOL smoke…
I’ve struggled with EVAP leaks for months until I got this AUTOOL smoke detector. Setup is a breeze, and smoke starts in seconds. The external gauges take the guesswork out of testing—I can see exactly if there’s a leak. No extra air pump needed, which saves time and money. It’s small, lightweight, and easy to store, plus the included adapters fit all my vehicles. The safety features are top-notch, and it works on my car, motorcycle, and ATV. If you need to find leaks quickly, this is the tool to buy!