AUTOOL LM708 · Dual-Circuit R134a and R1234yf Service Station

Service R134a and R1234yf in Separate Circuits

Service R134a and HFO-1234yf vehicles with independent refrigerant circuits and tanks. The 7-inch touchscreen guides recovery, evacuation, pressure/vacuum-hold checks and recharge, with three filling paths to suit the job. Five scales separately weigh both refrigerants, PAG oil, POE oil and used oil; a vehicle database, custom data and printed records support setup and service documentation.

  • Independent R134a / HFO-1234yf
  • 5 Separate Fluid Scales
  • 7-Inch Guided Touchscreen
  • 3 Filling Paths
  • Vehicle Data & Printed Records
AUTOOL LM708 automotive refrigerant freon recovery machine overview with dual systems, touchscreen, database, data printing and refrigerant cleaning

Funzionalità principali

Independent R134a and R1234yf Circuits

Independent Dual-Refrigerant Systems

LM708 is a dual-refrigerant machine for A/C service, with independent R134a and HFO-1234yf circuits and onboard tanks, reducing tank changes and cross-contamination risk.

Automatic Configured Workflow

After parameters are preset, LM708 runs recovery, evacuation, pressure/vacuum-hold leak checks, and recharge in sequence with touchscreen prompts.

Five Dedicated Scales

Weigh the two refrigerant tanks, PAG oil, POE oil and used oil separately.

Database dei veicoli

Start setup with a database of over 20,000 vehicle models or enter custom service data, then verify the values against the vehicle and current OEM information.

Protected New-Oil Storage

Oil-bottle design limits new oil’s exposure to ambient air/moisture; separate PAG, POE and used-oil positions organize handling.

Recovered-Refrigerant Cleaning

Filter and separator clean recovered refrigerant for reuse when condition, procedure and local rules allow.

Three Filling Methods

Select low-pressure, high-pressure or combined high- and low-pressure hose filling to suit the service procedure.

Schermo tattile da 7 pollici

Follow setup prompts and service status on the 7-inch touchscreen. Dedicated oil bottles and the built-in printer support fluid handling and job records.

Printed Service Records

Output maintenance data and operation records for the job file.

Four Languages

Choose English, German, Spanish or Chinese for the operating interface.

60 L/min Evacuation

Evacuate the system with the rated 60 L/min vacuum pump as part of the A/C service cycle.

100 kg Filter Cycle

Replace the filter-drier after each 100 kg of recovered refrigerant; use reset password 8609 only when the prescribed prompt is absent.

5 High-Precision Electronic Scales

Monitor R134a, HFO-1234yf, PAG oil, POE oil and used oil on five separate scales.

Potenza nominale

The LM708 is rated at 1100 W.

3 anni di garanzia e assistenza

Unità principale: 3 anni di garanzia. Accessori standard: 1 anno di garanzia. Politica di garanzia.

Istruzioni per l’uso:

Identify Refrigerant, Select Circuit, Service, and Verify

Progresso graduale1 / 6
01

Identify Refrigerant And Vehicle Requirements

Confirm R134a or HFO-1234yf, exact charge, PAG/POE oil and hybrid/EV procedures from reliable sources.

Sicurezza e compatibilità

Keep Refrigerant, Oil, Couplers, and Circuits Separate

Never Cross-Connect Refrigerants

Use the independent R134a or HFO-1234yf system matching the identified vehicle refrigerant.

Keep Overfill Protection Enabled

Do not disable protection; keep the specified tank on its load platform and use only manufacturer-approved tanks.

Indossare protezioni per occhi e mani

Liquid refrigerant can cause frostbite and eye injury; ventilate and follow the refrigerant/oil safety information.

Isolate Power For Service

Disconnect power before disassembly or maintenance and use grounded regional-nameplate power.

Confirm PAG/POE And High Voltage

For hybrid/EV work, follow the exact OEM oil chemistry and high-voltage procedure.

Follow Up the Hold Check

A failed automatic check requires inspection and separate approved diagnosis.

Extension Cable Conductor Size

Avoid extension power cables with a copper-core cross-section below 1.5 mm².

Tenere lontano da materiali infiammabili

Do not store gasoline or other flammable substances near the equipment.

Risultati del test

Verify Each Refrigerant Service Stage

Five Scale Records

After confirming the refrigerant and oil identity, use the five scales to document fluid movement during the selected service procedure and compare the amounts with the applicable OEM criteria.

Vacuum/Hold Result

If the hold check fails, verify the connections and continue with an approved leak-location method.

Database Values

Treat installed vehicle data as a starting point and verify against vehicle label/OEM information.

Printed Record

Document entered and measured service values, then complete any local recordkeeping requirements.

Post-Service Performance

Abnormal pressures or poor cooling require further electrical, airflow, mechanical or leak diagnosis.

Confronta modelli

Compare Single- and Dual-Refrigerant Stations

Guida al modello

Scegli uno o più modelli. LM708 è selezionato per impostazione predefinita.

1 modello selezionato

AUTOOL È stato selezionato LM708. Scegli un altro modello per un confronto affiancato.

Confronto LM708

Confronto di AUTOOL A/C Refrigerant Recovery & Recharge Machines
Ürün Adı LM708
Service Scope & Compatibility
Supported Refrigerant Types
HFO-1234yf / R-134a
Funzioni di base
Refrigerant Recharge, Refrigerant Recovery, Vacuum Pumping, Filling
Modalità automatica
Modelli di veicoli applicabili
Fuel Vehicles, Hybrid Vehicles, New Energy Vehicles
Interface & Equipment
Tensione di ingresso
Regional version; confirm the exact nameplate.
Display
Touchscreen da 7 pollici
Lingue disponibili
4
Aspetto del dispositivo
Built-in Refrigerant Tank, More Compact and Aesthetic Design
Added Back Panel for Direct Access to Maintenance
Fluid Handling & Capacity
Add Refrigerant Oil
Automatico
Refrigerant Recovery Rate
Confirm the recovery rate and measurement conditions for your version.
Capacità del serbatoio del refrigerante
Confirm each selected-version tank rating and permitted fill.
Number of Oil Bottles
3 (2 New oil bottle, 1 used-oil bottle)
Capacità della bottiglia dell'olio
350ml
Number of Electronic Scales
5
Filling Method Selection
HP/LP/HP+LP
Internal Refrigerant Circulation Purification
Records & Diagnostics
Stampa dei dati
Database integrato
Operation Record Inquiry
System Automatic Leak Detection
Automatic pressure/vacuum hold check; follow up a failed result with an approved leak-location method.

Manuale e download

Consultare il manuale per l'installazione e la manutenzione.

AUTOOL Copertina del manuale utente LM708
Manuale / PDF

AUTOOL Manuale utente LM708

Open the PDF manual for LM708 dual-refrigerant recovery, evacuation, recharge, fluid scales, filling methods, circuit separation, maintenance, safety, and troubleshooting.

AUTOOL LM708 packing list with machine, hoses, quick connectors, power cable and manual

CONFEZIONE

Cosa è incluso

  • Unità principale LM708Dual-system refrigerant recovery machine.
  • Red And Blue Service HosesService hoses for the matching refrigerant circuit.
  • R134a And HFO-1234yf Quick ConnectorsRefrigerant-specific couplers.
  • Regional Power CableConfirm plug and exact unit nameplate.
  • Manuale UtenteLM708 documentation.

DOMANDE FREQUENTI

Dual-Refrigerant Setup and Service Questions

What Refrigerants Does LM708 Support?

LM708 supports R134a and HFO-1234yf through independent refrigerant systems.

È in grado di identificare il refrigerante?

Confirm refrigerant and oil identity before selecting a service circuit; this unit does not identify the fluids.

What Is The Capacity Of Each Refrigerant System?

Published information lists 10 kg for each refrigerant system and also shows 12 kg × 2 internal tanks. Confirm both installed tank labels on the selected machine and follow their stated fill limits.

What do the five scales monitor?

R134a tank, HFO-1234yf tank, PAG oil, POE oil and used oil.

Is the database a substitute for OEM information?

No. Verify the installed record against the vehicle label and current OEM data.

Does automatic leak detection locate a leak?

No. Treat it as a pressure/vacuum-hold check and use separate approved diagnosis to find a leak.

Which charge paths are available?

LP, HP and combined HP+LP, used only when permitted by the service procedure.

When Should I Replace The Filter Drier?

Replace the filter drier for every 100kg of refrigerant recovered. Contact AUTOOL support when purchasing or replacing filter-related parts.

  • Replace it after each 100 kg of recovered refrigerant. Use 8609 only when the current manual calls for that reset and the prescribed prompt is absent.
Can it service hybrid and EV A/C?

Only compatible R134a or HFO-1234yf systems with the exact OEM oil and high-voltage procedure.

Does it print service records?

Yes, the built-in printer outputs maintenance/operation data.

Is LM708 Fully Automatic?

Yes. After presetting parameters, LM708 can automatically perform refrigerant recovery, vacuuming, leak detection, and refilling according to the selected workflow.

What Are The Three Refilling Methods?

LM708 supports LP low-pressure hose filling, HP high-pressure hose filling, and HP+LP combined filling.

What Is The Filter Reset Password?

After replacing the filter, reset it on the device page. If the device does not prompt you, enter the universal password 8609 to complete the operation.

Why Is Overfilling Protection Important?

The refrigerant tank contains liquid refrigerant. Overfilling may cause an explosion, so do not turn off overfilling safety protection. The refrigerant tank should always stay on the load unit platform during operation.

What Safety Gear Should I Wear?

Wear safety glasses and gloves. Liquid refrigerant contact may cause frostbite and blindness. If contact occurs, flush the affected area with plenty of water and consult a physician immediately.

Can I Use Any Refrigerant Tank?

No. Use only the special refrigerant tank recommended by the manufacturer.

Does LM708 Support Printing?

Yes. LM708 is equipped with a printer for maintenance data printing, operation records, and service documentation.

Recensioni

  1. TM

    Trevon McKenzie ✓ Acquisto verificato -

    Migliori AUTOOL LM708 is a reliable and efficient refrigerant machine.

    Migliori AUTOOL LM708 is a reliable and efficient refrigerant machine. It supports both R-134a and HFO-1234yf systems, making it versatile for different vehicles. The automatic recovery, evacuation, and charging functions make operation simple and convenient for automotive AC service

    0 of 0 trovato utile questa recensione
  2. AC

    Ada Chapman ✓ Acquisto verificato -

    Very nice machinery came packaged beautifully honestly and the delivery drivers…

    Very nice machinery came packaged beautifully honestly and the delivery drivers were great. 10/10 experience

    0 of 0 trovato utile questa recensione
  3. WM

    Wisnik Michal ✓ Acquisto verificato -

    Process Automated & Super Easy To Operate!!!

    Ho recentemente acquisito il AUTOOL LM708 Fully Automatic Machine for HVAC automotive recovery and recharge (designed for both R134 and HFO1234yf), and I must say it has exceeded all my expectations. Over the course of roughly thirty operational cycles, this machine has demonstrated exemplary reliability, operating flawlessly without even the slightest hiccup. Its robust construction and precision-engineered components inspire confidence; there has been no indication of leakage or mechanical compromise whatsoever.

    Beyond its mechanical resilience, the AUTOOL LM708 truly shines when it comes to user-friendliness. The interface is so intuitively structured and straightforward that even my children could navigate its functions—making it equally accessible for technicians of varying skill levels. The step-by-step automation streamlines the entire recovery and recharge process, minimizing the risk of user error and expediting workflow. It’s both refreshingly simple to set up and remarkably efficient to operate, which translates into valuable time savings in a professional garage environment.

    0 of 0 trovato utile questa recensione
Lascia Una Recensione

Il tuo indirizzo email non verrà pubblicato. I campi obbligatori sono contrassegnati da un asterisco (*).

AUTOOL Macchina per il recupero di R134a e R1234yf modello LM708.
AUTOOL Macchina per il recupero di R134a e R1234yf modello LM708.

US$5,999.00

Selezionare Questo prodotto ha più varianti. Le opzioni possono essere scelte sulla pagina del prodotto Richiesta di preventivo ufficiale
Ottieni uno sconto extra